Department of Engineering, Systems, and Services, Faculty of Technology, Policy, and Management, Delft University of Technology Jaffalaan 5 2628 BX Delft Netherlands M.D.M.Perez-Fortes@tudelft.nl. · Department of Chemical Engineering, Faculty of Applied Sciences, Delft University of Technology Van der Maasweg 9 2629 HZ Delft Netherlands.

Key points

From the paper's conclusion
  • To address this, we developed a two-stage linear optimization model to optimize the operation of a 540 MW electrolysis plant, alongside the sizing and operation of the connected renewable generation, battery storage, and syngas storage.

Abstract

Co-electrolysis of CO2 (CO2E) and water enables the production of syngas for sustainable aviation fuels (SAF) that are compliant with European RFNBO (renewable fuels of non-biological origin) regulations. However, a mismatch exists between the intermittent renewable electricity supply and the continuous operation of the downstream Fischer-Tropsch plants. To address this, we developed a two-stage linear optimization model to optimize the operation of a 540 MW electrolysis plant, alongside the sizing and operation of the connected renewable generation, battery storage, and syngas storage. Applying this model to a Dutch case study, we explored grid integration with an electrolyzer across future scenarios with global warming potentials (GWPs) ranging between 35 and 370 g CO2-eq per kWh. For generation, the preferred renewable mix is onshore wind combined with PV. When grid mix electricity consumption is restricted, the electrolyzer has an optimal capacity factor of 78% but requires a battery of comparable capacity to the electrolyzer and multi-kilotonne syngas storage to ensure continuous output. Crucially, we found that producing RFNBO-compliant syngas for SAF is impossible with the 2025 Dutch grid mix. Even at a reduced grid intensity of 205 g CO2-eq per kWh, RFNBO compliance limits grid consumption to just 1% of grid mix electricity per hour. This results in a levelized cost of 2350 EUR2019 per tonne syngas. Unrestricted grid electricity consumption becomes feasible when emissions drop below 36 g CO2-eq per kWh, reducing production costs by 43% (1344 EUR2019 per tonne syngas). Consequently, we demonstrate that grid composition intensity is a bottleneck for the short-term economic viability and regulatory compliance of CO2E-based SAF in the Netherlands.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Optimal sizing of renewable generation and storage for grid-connected CO2 electrolysis: a Dutch case study on syngas production for e-SAF — Science Skim