Optimal sizing of renewable generation and storage for grid-connected CO2 electrolysis: a Dutch case study on syngas production for e-SAF.
Thijmen Wiltink, Andrea Ramírez, Mar Pérez-Fortes
Department of Engineering, Systems, and Services, Faculty of Technology, Policy, and Management, Delft University of Technology Jaffalaan 5 2628 BX Delft Netherlands M.D.M.Perez-Fortes@tudelft.nl. · Department of Chemical Engineering, Faculty of Applied Sciences, Delft University of Technology Van der Maasweg 9 2629 HZ Delft Netherlands.
Key points
From the paper's conclusion- To address this, we developed a two-stage linear optimization model to optimize the operation of a 540 MW electrolysis plant, alongside the sizing and operation of the connected renewable generation, battery storage, and syngas storage.
Abstract
Co-electrolysis of CO2 (CO2E) and water enables the production of syngas for sustainable aviation fuels (SAF) that are compliant with European RFNBO (renewable fuels of non-biological origin) regulations. However, a mismatch exists between the intermittent renewable electricity supply and the continuous operation of the downstream Fischer-Tropsch plants. To address this, we developed a two-stage linear optimization model to optimize the operation of a 540 MW electrolysis plant, alongside the sizing and operation of the connected renewable generation, battery storage, and syngas storage. Applying this model to a Dutch case study, we explored grid integration with an electrolyzer across future scenarios with global warming potentials (GWPs) ranging between 35 and 370 g CO2-eq per kWh. For generation, the preferred renewable mix is onshore wind combined with PV. When grid mix electricity consumption is restricted, the electrolyzer has an optimal capacity factor of 78% but requires a battery of comparable capacity to the electrolyzer and multi-kilotonne syngas storage to ensure continuous output. Crucially, we found that producing RFNBO-compliant syngas for SAF is impossible with the 2025 Dutch grid mix. Even at a reduced grid intensity of 205 g CO2-eq per kWh, RFNBO compliance limits grid consumption to just 1% of grid mix electricity per hour. This results in a levelized cost of 2350 EUR2019 per tonne syngas. Unrestricted grid electricity consumption becomes feasible when emissions drop below 36 g CO2-eq per kWh, reducing production costs by 43% (1344 EUR2019 per tonne syngas). Consequently, we demonstrate that grid composition intensity is a bottleneck for the short-term economic viability and regulatory compliance of CO2E-based SAF in the Netherlands.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Composition-Tunable Power-to-Syngas: Techno-Economic and Sustainability AssessmentHydrogen · 2026
- Coupling PEM Electrolysis and Catalytic Methanation of Biogenic CO2 in Southern Spain: A Techno-Economic Feasibility StudyHydrogen · 2026
- Economic Viability of Drop-In SAF: Levelized cost of Fuel of e-Kerosene from Green Hydrogen and DAC CO 2Journal of Physics: Conference Series · 2026
- Optimal Design of an Off-Grid Wind–Solar Hydrogen Storage for Green Methanol Synthesis System Considering Multi-Factor CoordinationEnergies · 2026
- Life Cycle Assessment of Solid Oxide Fuel Cell System for Sustainable Power Generation: A ReviewEnergy Technology · 2026
- Fueling a green future: unlocking the environmental potential of CO₂ -derived power-to-X liquid fuels via life cycle assessmentRSC Sustainability · 2026