Analytical methods : advancing methods and applications

Fe3O4@NA@MIPs-based molecularly imprinted nanozyme colorimetric platform with smartphone-assisted RGB readout for BPA detection.

Jinwen Zhao, Le Wang, Siqing Zhang, Yanqin Zhu, Qinhong Yin

Faculty of Materials Science and Engineering, Kunming University of Science and Technology, Kunming 650093, PR China. 20070029@kust.edu.cn. · Key Laboratory of Intelligent Drug Control, Ministry of Education, Yunnan Key Laboratory of Intelligent Drug Control, Faculty of Narcotics Control, Yunnan Police College, Kunming 650223, PR China. hawkyin2008@126.com.

Key points

From the paper's conclusion
  • Based on this, a colorimetric detection method for BPA can be developed using the Fe3O4@NA@MIPs-H2O2-TMB system.

Abstract

Bisphenol A (BPA) is a well-known endocrine-disrupting chemical widely used in various industrial processes, posing a significant threat to human health and the environment. By integrating molecular imprinting technology with nanozymes, a simple colorimetric detection method specific for BPA has been developed. Fe3O4@NAs, a smart nanozyme consisting of magnetic Fe3O4 nanoparticles coated with a copolymer of norepinephrine and m-phenylenediamine (NAs), possesses intrinsic magnetic separation properties and high-efficiency catalysis. Using BPA as the template, 3-aminopropyltriethoxysilane as the functional monomer, and tetraethyl orthosilicate as the crosslinking agent, molecularly imprinted polymers (MIPs) were synthesized on the surface of Fe3O4@NAs particles via the sol-gel method. The prepared Fe3O4@NA@MIPs exhibits outstanding peroxidase-like activity, catalyzing the oxidation of colorless 3,3',5,5'-tetramethylbenzidine (TMB) to blue oxidized TMB (oxTMB) in the presence of H2O2. In the presence of BPA, Fe3O4@NA@MIPs selectively adsorbs BPA, leading to the blocking of catalytic sites on its surface. This leads to a decrease in its peroxidase-like activity. Based on this, a colorimetric detection method for BPA can be developed using the Fe3O4@NA@MIPs-H2O2-TMB system. This method has a linear detection range of 9.98-600 nM and a detection limit as low as 2.99 nM. This sensor has been successfully applied to the quantitative determination of BPA in bottled water, with recovery rates ranging from 96.0% to 110.0%. This work proposes a practical and innovative approach for developing a visual colorimetric detection sensor system integrated with a smartphone-based visual inspection platform for monitoring trace amounts of BPA.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers