From in situ collection to microsequential injection: determination of iron in water.
Mafalda G Pereira, Tânia C F Ribas, Tânia Moniz, Maria Rangel, Raquel B R Mesquita, António O S S Rangel
Universidade Católica Portuguesa, CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Rua de Diogo Botelho 1327, 4169-005 Porto, Portugal. rmesquita@ucp.pt. · LAQV, REQUIMTE, Instituto de Ciências Biomédicas de Abel Salazar, Universidade do Porto, Rua de Jorge Viterbo Ferreira 228, 4050-313 Porto, Portugal.
Key points
From the paper's conclusion- A miniaturized smart sampling method for the determination of iron in environmental waters was developed, integrating beads for in situ collection and microsequential injection lab-on-valve for the analysis (µSI-LOV).
Abstract
A miniaturized smart sampling method for the determination of iron in environmental waters was developed, integrating beads for in situ collection and microsequential injection lab-on-valve for the analysis (µSI-LOV). To selectively retain iron(III) from water samples, nitrilotriacetic acid (NTA) beads were employed. Then, the sorbent was subsequently incorporated in a microsequential injection system, and a hydroxypyridinone ligand (MRB13) was used to chelate iron and produce a coloured product to be measured at the flow cell. The iron quantification was achieved using two approaches: (i) a direct determination in the µSI-LOV and (ii) using a bead injection approach (BI-µSI-LOV). The limit of detection (LOD) and limit of quantification (LOQ) were 0.053 and 0.18 mg L-1 for the µSI-LOV, and 0.037 and 0.10 mg L-1 for the BI-µSI-LOV, respectively, enabling a quantification range from 0.10-1.0 mg L-1. The developed methods were validated by application to certified water samples, with results consistent with the certified values. Additionally, the methods were applied to various types of spiked water samples, with the results compared with those of the atomic absorption spectrometry reference procedure and used to perform recovery studies (percentages between 90 and 110% were obtained) for further validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Multiplex measurement system for the detection of nutrients in hydroponics using ion-selective electrodesJournal of Sensors and Sensor Systems · 2026
- Online extraction and preconcentration system employing a mini-column packed with 4-(2-thiazolylazo)-resorcinol-coated CoFe2O4 nanoparticles for the determination of lead in water samples by F AAS.Talanta · 2026
- Ultrasound-assisted dispersive solid-phase extraction of Ultratrace Fe(III) and Cr(III) from environmental waters using modified nanoporous MCM-41 as a novel adsorbentResults in Chemistry · 2026
- Machine learning-assisted nitrogen-doped carbon dots for Fe3+ detection in aqueous environments.Analytical methods : advancing methods and applications · 2026
- Early-stage nanoparticle-metal interactions under flow: real-time, sub-second monitoring by microfluidic-ICP-MS.Journal of colloid and interface science · 2026
- Electrokinetic detection of organic contaminants using molecularly imprinted polymer particles in microchannels.Mikrochimica acta · 2026