Analytical methods : advancing methods and applications

Image based chemical identification of ophthalmic antibiotics.

Alisha Bogati, Sanam Pudasaini, Beni B Dangi, Basant Giri

Center for Analytical Sciences, Kathmandu Institute of Applied Sciences, P.O. Box 23002, Kathmandu, Nepal. bgiri@kias.org.np. · Department of Chemistry, Florida Agricultural and Mechanical University, Tallahassee, FL 32307, USA.

Key points

From the paper's conclusion
  • A total of 46 quantitative image features were extracted from each dried deposit, capturing texture, morphology, and intensity variations arising from formulation-specific physicochemical behavior.

Abstract

Substandard and falsified medicines remain a significant global health challenge. While conventional analytical quality control methods such as high-performance liquid chromatography are accurate and reliable, they are often costly, infrastructure-dependent, and unsuitable for resource-limited settings. In this study, we present a low-cost analytical framework based on evaporation-induced deposit imaging combined with machine learning for the identification and quantification of five commercial ophthalmic formulations. Droplets of each formulation were deposited on glass slides, dried under controlled environmental conditions, and imaged. A total of 46 quantitative image features were extracted from each dried deposit, capturing texture, morphology, and intensity variations arising from formulation-specific physicochemical behavior. The evaporation process produced distinct crystallization patterns, including coffee-ring structures, dendritic growth, and spherulitic morphologies, allowing the formulations to be clearly distinguished both visually and statistically. Principal component analysis separated all five drugs into distinct clusters, with the first three principal components explaining 65.6% of total variance. For quantitative analysis, we applied XGBoost and EfficientNet-B3 models to standard dilution images of ciprofloxacin and moxifloxacin. Within the tested concentration ranges, both models performed well, yielding regression slopes close to unity (0.89-0.95) and R2 values as high as 0.98. Evaluation of models using R2, MAE, and MSE metrics confirmed the models' accuracy. Validation on real samples showed that the models generalized effectively, although prediction error increased due to more complex samples. These results offer a proof-of-concept for using macroscopic images to extract chemical information.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers