Talanta

Experimental design-guided deep learning for microscopy-based qualitative classification of assay-referenced glipizide powder-blend states: A proof-of-concept study.

Shubham Sutradhar, Swayamprakash Patel, Jagruti Desai, Amit Thakkar, Abhishek Patel

Department of Pharmaceutical Technology, Ramanbhai Patel College of Pharmacy, Charotar University of Science and Technology (CHARUSAT), CHARUSAT Campus, Changa, 388421, India. Electronic address: 24drfph002@charusat.edu.in. · Department of Pharmaceutical Technology, Ramanbhai Patel College of Pharmacy, Charotar University of Science and Technology (CHARUSAT), CHARUSAT Campus, Changa, 388421, India. Electronic address: Swayamprakash.patel@gmail.com.

Computational

Key points

From the paper's conclusion
  • The findings support further evaluation of microscopy-assisted CNN classification as a complementary, reagent-minimized screening strategy rather than a replacement for validated quantitative analysis.

Abstract

Microscopic imaging could complement conventional powder-blend analysis by providing a rapid qualitative signal from physical particle patterns. This proof-of-concept study examined whether 10× light-microscopy images can distinguish assay-qualified glipizide powder blends generated under contrasting mixing conditions. Five batches prepared by geometric dilution and ordered mixing and 25 batches prepared by short-duration direct mixing were retained after three independent powder samples per batch satisfied prespecified class-specific assay criteria. For the Mixed reference class, all three sample assays had to fall within 90-110% of target; for the Not Mixed class, all three had to lie outside this interval. The preliminary CNN comparison used 1802 original images (951 Mixed and 851 Not Mixed). Five pretrained CNN architectures, three input resolutions and four online augmentation levels formed a 60-configuration mixed-level factorial screen. DenseNet-121 with 1024 × 1024-pixel inputs and nominal 50× augmentation yielded the highest reported preliminary F1-score (0.9748; accuracy 0.9732). The methanolic UV reference method was linear over 5-60 μg/mL (R2 = 0.99998), showed negligible placebo interference, and gave 99.88-100.08% mean recovery across 80-120% spike levels. Continued image acquisition yielded a documented inventory of 3093 images (1438 Mixed and 1655 Not Mixed), partitioned into 2165 training and 928 validation images. Because batch-of-origin identifiers were not retained after class-wise image pooling, independently held-out batch performance could not be established. Post hoc Grad-CAM analysis on a reserved 120-image set showed representative attention within particulate regions without establishing chemical specificity or excluding protocol-associated morphology. MoGAPI assessment yielded a score of 81 for the proposed microscopy-CNN screening workflow versus 64 for the UV reference procedure. The findings support further evaluation of microscopy-assisted CNN classification as a complementary, reagent-minimized screening strategy rather than a replacement for validated quantitative analysis.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers