Analytical methods : advancing methods and applications

An antibody-functionalized N-CQD-based "Off-On" fluorescent probe for serum C3M detection: a proof-of-concept study toward postoperative joint rehabilitation assessment.

Shang Wu, Kai Feng, Yu Zhang, Yi Zhou, Letao Jiang, Jianwei Du, Jing Wang

Department of Orthopedics, The Affiliated Hospital of Yangzhou University, Yangzhou University, Yangzhou, Jiangsu, 225000, China. doctorduyz@163.com. · Department of Rehabilitation Medicine, The Affiliated Hospital of Yangzhou University, Yangzhou University, Yangzhou, Jiangsu, 225000, China. 15062816672@163.com.

Key points

From the paper's conclusion
  • Here, we developed an "Off-On" fluorescent sensing system based on antibody-functionalized nitrogen-doped carbon quantum dots (N-CQDs) for sensitive detection of serum C3M, a type II collagen degradation fragment, as a preliminary approach toward postoperative joint rehabilitation assessment.

Abstract

Monitoring postoperative rehabilitation progress following joint surgery remains a clinical challenge due to the lack of rapid, quantitative, and dynamic biomarkers. Here, we developed an "Off-On" fluorescent sensing system based on antibody-functionalized nitrogen-doped carbon quantum dots (N-CQDs) for sensitive detection of serum C3M, a type II collagen degradation fragment, as a preliminary approach toward postoperative joint rehabilitation assessment. The N-CQDs were synthesized via a one-step hydrothermal method using citric acid and urea as precursors, with an emission maximum at 460 nm. Anti-C3M monoclonal antibodies were covalently conjugated to the N-CQDs surface via EDC/NHS chemistry. The fluorescence of the resulting Ab-N-CQDs probe was quenched by BHQ-1-labeled specific peptides through FRET, forming the "Off" state. Upon addition of target C3M, competitive antigen-antibody binding displaced the quencher-labeled peptide, restoring fluorescence ("On" state). The sensor showed a linear range of 10-100 ng mL-1, a detection limit of 0.05 ng mL-1, and good selectivity. Preliminary method comparison with a commercial C3M ELISA using all available serum samples (n = 9) showed a strong correlation (Spearman ρ = 0.95, p < 0.001) and a mean bias of -0.44 ng mL-1 by Bland-Altman analysis. In a pilot proof-of-concept study with 9 participants (4 healthy controls and 5 patients), C3M levels were significantly elevated in patients, with distinct temporal profiles at postoperative days 1, 3, 7, and 14. This sensitive and simple assay provides a promising approach for serum C3M detection and may be potentially adaptable to point-of-care testing in the future, although the current method still requires laboratory fluorescence instrumentation and a 40-min incubation. However, the small sample size precludes any conclusion regarding rehabilitation assessment; larger studies with standardized rehabilitation endpoints are required.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.