Ratiometric Fluorescent Sensing of MMP-3 via FRET for Postoperative Rehabilitation Assessment and Prognostic Monitoring Following Joint Surgery.
Letao Jiang, Kai Feng, Yu Zhang, Yi Zhou, Shang Wu, Jianwei Du, Jing Wang
Department of Orthopedics, The Affiliated Hospital of Yangzhou University, Yangzhou University, Yangzhou, 225000, Jiangsu, China. · Department of Orthopedics, The Affiliated Hospital of Yangzhou University, Yangzhou University, Yangzhou, 225000, Jiangsu, China. doctorduyz@163.com.
Key points
From the paper's conclusion- These results demonstrate that our ratiometric FRET probe holds promise for postoperative rehabilitation assessment and prognostic monitoring following joint surgery.
Abstract
Matrix metalloproteinase-3 (MMP-3) is a critical biomarker for inflammatory responses and tissue remodeling following joint surgery. Here, we developed a ratiometric fluorescence probe based on fluorescence resonance energy transfer (FRET) for sensitive and selective detection of MMP-3 activity. The probe comprises CdTe quantum dots (R-QDs) as the energy donor and BHQ as the acceptor, linked by an MMP-3-cleavable peptide. Upon MMP-3 cleavage, the FRET process is disrupted, resulting in fluorescence recovery at 540 nm, while the reference signal at 690 nm remains constant, enabling ratiometric quantification. The probe exhibits a linear response from 20 to 100 nM with a detection limit of 7.8 nM and excellent selectivity against other MMPs and interfering proteins. Clinical validation using serum samples from 11 subjects (5 healthy controls and 6 post-surgery patients) successfully distinguished patients from controls. Moreover, real-time monitoring of 6 patients over 18 days post-surgery revealed a clear correlation between MMP-3 levels and rehabilitation progress. These results demonstrate that our ratiometric FRET probe holds promise for postoperative rehabilitation assessment and prognostic monitoring following joint surgery.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Matrix Metalloproteinase-9-Activated Dually-Quenched Fluorescence Nanoprobe for Sensitive Imaging of Rheumatoid Arthritis.Analytical chemistry · 2026
- An antibody-functionalized N-CQD-based "Off-On" fluorescent probe for serum C3M detection: a proof-of-concept study toward postoperative joint rehabilitation assessment.Analytical methods : advancing methods and applications · 2026
- Construction of Matrix Metalloproteinase-13-Activatable cRGD-Targeted Ratiometric Fluorescent Nanoprobe for Imaging Microscopic Osteosarcoma Lesions and Pulmonary Metastases.ACS nanoscience Au · 2026
- Interface-Stabilized Logic Nanoprobe Enables High-Fidelity Orthogonal Sensing of MMP-1 and HNE in Thiol-Rich Biological Environments.ACS sensors · 2026
- Activated Fluorescent Probe for Long‐Term Imaging and Surgical Navigation via Enzyme‐Mediated Fluorogenic Reaction and Self‐AssemblyAdvanced Functional Materials · 2025
- Activity-based probes to detect MMP activity.The Enzymes · 2026