Electrochemical ultrasensitive detection of miRNA-21 via RAFT/ROMP dual polymerization amplification.
Jiaxun Zhang, Shijin Zhou, Jinming Kong, Xueji Zhang
School of Environmental and Biological Engineering, Nanjing University of Science and Technology, Nanjing 210094, China. j.kong@njust.edu.cn. · School of Biomedical Engineering, Shenzhen University Health Science Center, Shenzhen 518060, China.
Key points
From the paper's conclusion- Herein, we design an electrochemical biosensor based on a dual-signal amplification strategy utilizing reversible addition-fragmentation chain transfer (RAFT) and ring-opening metathesis polymerization (ROMP) to achieve ultra-sensitive quantitative detection of miRNA-21.
Abstract
The ultrasensitive detection of microRNAs in bodily fluids is crucial for early diagnosis of cancer. Herein, we design an electrochemical biosensor based on a dual-signal amplification strategy utilizing reversible addition-fragmentation chain transfer (RAFT) and ring-opening metathesis polymerization (ROMP) to achieve ultra-sensitive quantitative detection of miRNA-21. The sensing interface starts from a gold electrode carrying a thiol-immobilized peptide nucleic acid (PNA) capture probe. Once miRNA-21 hybridizes specifically with the PNA, we anchor the RAFT chain-transfer agent 2-(dodecylthiocarbonothioylthio)-2-methylpropionic acid (CDTPA) onto the duplex by taking advantage of Zr4+ coordination chemistry. With the azo initiator 2,2'-azobis[2-(2-imidazolin-2-yl) propane] dihydrochloride (VA-044), in solution, the monomer dicyclopentenyloxyethyl acrylate (DCPEA)-which bears a cyclopentene side group-undergoes RAFT polymerization, decorating the duplex with polymer chains that bristle with pendant cyclopentene rings. Subsequently, the ruthenium-based catalyst AquaMet ((4-((4-ethyl-4-methylpiperazin-1-ium-1-yl)methyl)-1,3-dimesitylimidazolidin-2-ylidene)dichloro(2-isopropoxybenzylidene) ruthenium(II)) chloride coordinates with the cyclopentene groups, catalyzing the ROMP of cyclopentene-based ferrocene (CFc), thereby forming a polymer brush rich in ferrocene electroactive molecules on the electrode surface, achieving efficient two-stage amplification of the electrochemical signal. Under optimized conditions, the sensor returns a linear response to miRNA-21 from 10-17 M to 10-13 M and reaches a detection limit as low as 4.72 aM. Signals from single-mismatched RNA, triple-mismatched RNA, and miRNA-320b were all strongly suppressed relative to the target, while the sensor also proved to be stable in one week and remarkably unfazed by complex biological backgrounds.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ultrasensitive miRNA-21 biosensing: a metal-free photoinduced ROMP strategy via 3'-end oxidation.Analytical and bioanalytical chemistry · 2026
- Bioinspired Compartmentalization Coupled with DNA-Gated Magnetic Nanoprobes Enables Simultaneous Electrochemical Detection of Dual MicroRNAs.Analytical chemistry · 2026
- Bifunctional CuPt Nanoclusters and DSN-Mediated Target Recycling Enabled Dual-Mode OPECT/Colorimetric Biosensing for Ultrasensitive and Wide-Range Detection of miRNA-21.Analytical chemistry · 2026
- Synergistic cascade amplification by catalytic hairpin assembly and terminal deoxynucleotidyl transferase for ultrasensitive detection of microRNA-21.Talanta · 2026
- Dual-Functional Nanoconfined Metal-Organic Frameworks with Aggregation-Induced Electrochemiluminescence Coupled with DNAzyme Motor for Ultrasensitive miRNA-21 Biosensing.Small (Weinheim an der Bergstrasse, Germany) · 2026
- Cooperative DSN-Cas12a cascade and Cu/Zr-MOF nanozyme for label-free electrochemical detection of circulating exosomal miR-21 in colorectal cancer.Mikrochimica acta · 2026