Analytical methods : advancing methods and applications

Carbon dioxide-switchable hydrophilicity-assisted lighter-than-water deep eutectic solvent-based liquid-phase microextraction of triazine herbicides from aqueous samples performed in a narrow tube before GC-FID analysis.

Alaa Anwer Ali Dada, Abdolhossein Naseri, Mohammad Reza Afshar Mogaddam, Mir Ali Farajzadeh

Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran. ab.naseri@gmail.com. · Food and Drug Safety Research Center, Pharmaceutical Sciences Institute, Tabriz University of Medical Sciences, Tabriz, Iran. mr.afsharmogaddam@yahoo.com.

Key points

From the paper's conclusion
  • Notably, the procedure required no additional cleanup or solvent evaporation steps and consumed only 130 µL of a biodegradable, low-toxicity deep eutectic solvent, aligning well with the principles of green analytical chemistry.

Abstract

Triazine herbicides are widely used agricultural chemicals with high environmental persistence and potential ecotoxicological hazards, necessitating sensitive, precise, and cost-effective analytical methods for their monitoring in water matrices. In this work, a new carbon dioxide-switchable liquid-phase microextraction technique was introduced, leveraging the reversible hydrophilicity transition of an aromatic amine-based deep eutectic solvent for the efficient extraction of simazine, atrazine, and terbutryn from aqueous samples. The menthol : 4-amino-1-naphthol deep eutectic solvent was selected as the optimal extractant due to its favorable switchable behavior, low viscosity, and strong affinity for triazines through π-π, hydrogen bonding, and hydrophobic interactions. Following CO2-induced phase switching and ultrasonication-assisted coalescence, the final organic phase was directly injected into a gas chromatograph equipped with a flame ionization detector. Under optimum conditions, the proposed method provided acceptable extraction recoveries (66-74%) and high enrichment factors (641-719), with low limits of detection (0.17-0.31 ng mL-1) and satisfactory intra- and inter-day precisions (relative standard deviations ≤7.1%). Linear calibration curves were obtained over a concentration range of 1-500 ng mL-1, with coefficients of determination ≥0.995. The method was successfully validated by analyzing real environmental water samples, including river water, tap water, surface water, groundwater, and dam water, with spiked recoveries ranging from 83% to 106%, confirming its robustness in these samples. The samples were free of the analytes. Notably, the procedure required no additional cleanup or solvent evaporation steps and consumed only 130 µL of a biodegradable, low-toxicity deep eutectic solvent, aligning well with the principles of green analytical chemistry.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers