An interface-engineered signal-on electrochemical aptasensor for H5N2 avian influenza virus detection.
Thi Thanh-Thao Dang, Sang Hoon Kim, Bang Hyun Lee, Jungbae Kim, Chang-Seon Song, Man Bock Gu
Department of Biotechnology, College of Life Sciences and Biotechnology, Korea University, Anam-dong, Seongbuk-gu, Seoul, Republic of Korea. mbgu@korea.ac.kr. · University of North Carolina - Chapel Hill, Department of Applied Physical Sciences, 1112 Murray Hall, CB#3050, Chapel Hill, NC 27599-2100, USA.
Key points
From the paper's conclusion- These results support the feasibility of converting a previously validated H5N2 aptamer pair into a quantitative electrochemical platform for surveillance-oriented virus detection.
Abstract
Outbreaks of avian influenza virus (AIV) cause substantial economic losses in the poultry industry, highlighting the need for sensitive, reliable and field-adaptable detection platforms. In this study, we report a signal-on electrochemical aptasensor for avian influenza virus H5N2(K08-404) by translating a previously reported J3/JH4 cognate aptamer pair into an electrode-confined sandwich sensing format. The simultaneous binding capability of this aptamer pair enabled target-mediated recruitment of the HRP-labeled reporter aptamer and generated a signal-on amperometric response. This signal-on aptasensor was successfully fabricated by immobilizing the primary aptamer on the screen-printed gold electrode followed by the addition of a mixture of the target virus and the secondary aptamer labeled with horseradish peroxidase, thereby generating amplified signal-on electrochemical responses. The fabrication of the sandwich-type aptasensor was characterized by cyclic voltammetry and electrochemical impedance spectroscopy. Decreased peak currents and increased peak-to-peak separation supported the stepwise assembly of the electrochemical sensing interface. Analytical performance was evaluated at various virus concentrations using chronoamperometry, revealing a concentration-dependent increase in current response. The aptasensor achieved LODs of 2.00 × 104 EID50 per mL in a buffer and 2.76 × 104 EID50 per mL in a processed duck fecal matrix, with linear working ranges of 3.91 × 104-4.17 × 105 EID50 per mL and 1.95 × 104-1.25 × 106 EID50 per mL, respectively. These results support the feasibility of converting a previously validated H5N2 aptamer pair into a quantitative electrochemical platform for surveillance-oriented virus detection.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A paper-based electrochemical aptasensor functionalized with silver nanoparticles for the detection of African swine fever virus p30 protein.Biochemical and biophysical research communications · 2026
- Cascade signal amplification-based electrochemical aptasensor for sensitive detection of enrofloxacin in animal-derived foods.Talanta · 2026
- Simultaneous and sensitive detection of Mycobacterium tuberculosis and SARS-CoV-2 antigens employing an electrochemical impedance spectroscopy aptasensorFrontiers in Bioengineering and Biotechnology · 2025
- Dual-aptamer magnetic capture and electrochemical detection of influenza B and respiratory syncytial viruses in artificial saliva.The Analyst · 2026
- General approach to achieving electrochemical aptamer-based sensor sensitivity of buffer in blood plasmanpj Biosensing · 2026
- From Bench to Bedside: Clinical Translation of Electrochemical Biosensors for Viral Diagnostics.Diagnostics (Basel, Switzerland) · 2026