The Analyst

An interface-engineered signal-on electrochemical aptasensor for H5N2 avian influenza virus detection.

Thi Thanh-Thao Dang, Sang Hoon Kim, Bang Hyun Lee, Jungbae Kim, Chang-Seon Song, Man Bock Gu

Department of Biotechnology, College of Life Sciences and Biotechnology, Korea University, Anam-dong, Seongbuk-gu, Seoul, Republic of Korea. mbgu@korea.ac.kr. · University of North Carolina - Chapel Hill, Department of Applied Physical Sciences, 1112 Murray Hall, CB#3050, Chapel Hill, NC 27599-2100, USA.

Key points

From the paper's conclusion
  • These results support the feasibility of converting a previously validated H5N2 aptamer pair into a quantitative electrochemical platform for surveillance-oriented virus detection.

Abstract

Outbreaks of avian influenza virus (AIV) cause substantial economic losses in the poultry industry, highlighting the need for sensitive, reliable and field-adaptable detection platforms. In this study, we report a signal-on electrochemical aptasensor for avian influenza virus H5N2(K08-404) by translating a previously reported J3/JH4 cognate aptamer pair into an electrode-confined sandwich sensing format. The simultaneous binding capability of this aptamer pair enabled target-mediated recruitment of the HRP-labeled reporter aptamer and generated a signal-on amperometric response. This signal-on aptasensor was successfully fabricated by immobilizing the primary aptamer on the screen-printed gold electrode followed by the addition of a mixture of the target virus and the secondary aptamer labeled with horseradish peroxidase, thereby generating amplified signal-on electrochemical responses. The fabrication of the sandwich-type aptasensor was characterized by cyclic voltammetry and electrochemical impedance spectroscopy. Decreased peak currents and increased peak-to-peak separation supported the stepwise assembly of the electrochemical sensing interface. Analytical performance was evaluated at various virus concentrations using chronoamperometry, revealing a concentration-dependent increase in current response. The aptasensor achieved LODs of 2.00 × 104 EID50 per mL in a buffer and 2.76 × 104 EID50 per mL in a processed duck fecal matrix, with linear working ranges of 3.91 × 104-4.17 × 105 EID50 per mL and 1.95 × 104-1.25 × 106 EID50 per mL, respectively. These results support the feasibility of converting a previously validated H5N2 aptamer pair into a quantitative electrochemical platform for surveillance-oriented virus detection.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers