Dual-aptamer magnetic capture and electrochemical detection of influenza B and respiratory syncytial viruses in artificial saliva.
Dide Su Demirel, Naci Polat, Hakan Eligul, Elif Esra Altuner, Ali Dogan Dursun, Gunes Kibar, Zeynep Yegin, Barbaros Çetin,
Medicana International Hospital Ankara, Söğütözü, 06520 Ankara, Turkiye. · Dep. of Pathophysiology, Faculty of Medicine, Ankara University, Ankara, Turkiye.
Key points
From the paper's conclusion- We report a dual-aptamer magnetic-capture electrochemical assay for detection of influenza B virus (IBV) and human respiratory syncytial virus (hRSV) in artificial saliva.
Abstract
Saliva is a promising non-invasive specimen for respiratory virus diagnostics but its biochemical complexity challenges direct interfacing with affinity-based biosensors. We report a dual-aptamer magnetic-capture electrochemical assay for detection of influenza B virus (IBV) and human respiratory syncytial virus (hRSV) in artificial saliva. For each target virus, two sequence-distinct DNA aptamers are used: an amino-modified capture aptamer (IBV1 or RSV1) covalently coupled to ∼5 µm polydopamine-coated magnetic microparticles by direct Schiff-base reaction with the polydopamine quinone/catechol surface, and a thiol-modified detection aptamer (IBV2 or RSV2) self-assembled on screen-printed gold electrodes via thiol-gold chemistry. After a single multiplexed batch capture step with both aptamer-magnetic-particle types, the pellet is split and analysed in parallel on the two aptamer-modified electrodes by square-wave voltammetry (SWV). Langmuir analysis of the SWV calibration curves yielded apparent dissociation constants of Kd = 177 ± 62 PFU mL-1 (IBV) and 226 ± 85 PFU mL-1 (hRSV), with detection limits of 15 and 11 PFU mL-1, respectively. Log-linear calibration spanned 101-104 PFU mL-1 on both channels (n = 4 concentrations, R2 = 0.995 and 0.990) with sensitivities of 8.58 and 6.61 µA per decade, so that each virus-specific assay covers three orders of magnitude of viral load. The sequence-orthogonal dual-aptamer geometry-capture and detection recognitions targeting non-identical epitopes-is proposed as the structural mitigation. This proof-of-concept establishes a programmable, saliva-compatible architecture reconfigurable for emerging respiratory pathogens by aptamer substitution alone.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- From Bench to Bedside: Clinical Translation of Electrochemical Biosensors for Viral Diagnostics.Diagnostics (Basel, Switzerland) · 2026
- Multiplexed Detection of Respiratory Viruses Using Surface Plasmon Resonance Spectroscopy With Ultrathin Carbon Nanomembranes.Advanced healthcare materials · 2026
- Capillary-Driven Duplex Microfluidic Device Enabling Simultaneous Electrochemical Immunoassays for Detecting SARS-CoV-2 and Respiratory Syncytial VirusACS Sensors · 2026
- Disposable Point of Care multiplexed plasmonic biosensor for rapid and specific identification of respiratory virusesnpj Biosensing · 2026
- Rapid Detection of Dextromethorphan in Saliva and E-Juice Based on Highly Selective Aptamers.Analytical chemistry · 2026
- Affinity Peptide-Engineered Magnetic Microswimmers for Ultrafast On-the-Fly Screening of Influenza A Virus in Microliter-Scale Samples.ACS sensors · 2026