Key points
From the paper's conclusion- These results suggest that 1-lead ECGs, when combined with explainable AI, have the potential to support broader clinical applications and empower patients, particularly in resource-limited or remote settings where access to traditional cardiac diagnostics remains constrained.
Abstract
Traditional 12-lead ECGs offer comprehensive insights into the electrical activity of the heart, but require clinical settings and expert interpretation, which limits their accessibility. Smartwatch 1-lead ECGs can be recorded at home, allowing more frequent and rapid monitoring, opening opportunities for early adverse event detection and enhanced patient autonomy. This study investigates whether 1-lead ECGs can provide clinically meaningful information beyond heart rhythm assessment. Using explainable deep learning models, we predict left ventricular function (LVF) from both 1-lead and 12-lead ECGs in a post-myocardial infarction population, and compare their respective performances. Our findings demonstrate that LVF can be accurately predicted from 1-lead ECGs alone (AUC = 0.883), nearly matching the predictive performance of 12-lead ECGs (AUC = 0.897). Explainability analyses further reveal that the models leverage physiologically plausible ECG features, supporting the validity of this approach. These results suggest that 1-lead ECGs, when combined with explainable AI, have the potential to support broader clinical applications and empower patients, particularly in resource-limited or remote settings where access to traditional cardiac diagnostics remains constrained.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Patient experiences with a smartwatch 1L-ECG versus traditional Holter monitoring for ambulatory cardiac rhythm monitoring: a qualitative studyBMJ Open · 2025
- Explainable AI for automatic heart disease diagnosis using 3DFMMecg features: A novel ECG-based approachBiomedical Signal Processing and Control · 2025
- Diagnostic accuracy of multivector smartwatch electrocardiography compared with conventional 12-lead ecgEuropean Heart Journal · 2026
- Generation of 12-Lead Electrocardiogram Using Smartwatches in Patients With Cardiac Conditions: Clinical Validation Study.JMIR cardio · 2026
- Study protocol for The Heart Watch Study - Prognostic performance of smartwatch 12-lead ECG with advanced ECG analysis in consumer self-screening for cardiovascular disease.American heart journal · 2026
- Detecting low left ventricular ejection fraction from ECG using an interpretable and scalable predictor-driven framework: a model development and validation studyEClinicalMedicine · 2026