Analysis of real-world eye level light exposure through spectacle lens.
Emmanuel Kobia-Acquah, Camille Prince, Eléonore Pic, Des Coughlan, Joshua Hazle, Coralie Barrau
Neuroscience and Medical Research, EssilorLuxottica, Paris, France. ekobiaacquah@essilorluxottica.id. · Neuroscience and Medical Research, EssilorLuxottica, Paris, France.
Key points
From the paper's conclusion- This study presents a simulation-based methodology for evaluating lens-modulated light exposure across diverse real-world environmental conditions.
Abstract
This study presents a simulation-based methodology for evaluating lens-modulated light exposure across diverse real-world environmental conditions. A total of 987 outdoor light conditions were captured using calibrated spectroradiometers in 12 countries, recording spectral irradiance (280-780 nm, 1-nm resolution) and illuminance without lenses. Conditions varied by geographic region, weather, head inclination, and solar orientation. A lens transmittance model assigned transmittance values based on ambient illuminance and temperature to simulate the illuminance reaching the eye through clear, sun, and light-adaptive lenses. Melanopic equivalent daylight illuminance (EDI) was also computed to assess biologically relevant light exposure. Mean ambient illuminance was 42,561 ± 45,480 lux (range: 266-288,178) and 5934 ± 6738 lux (243-6738 lux) after light-adaptive lens simulation, with significant variations across environmental conditions. High-illuminance exposure (>10,000 lux) decreased from 68% (clear) to 6% (light-adaptive lens), while exposure between 1000 and 10,000 lux increased from 30% to 90%, and low-illuminance (<1000 lux) remained low (1.7% vs 3.1%). Melanopic analysis showed largely preserved melanopic EDI, with only 6% of conditions falling below 250 melanopic EDI. Light-adaptive lens reduced high-intensity light while maintaining moderate daylight levels and melanopic EDI. This methodology provides a more ecologically valid evaluation of lens performance than conventional lab-based testing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A calibration pipeline for controlled ocular photostimulation with consumer see-through extended-reality glassesmedRxiv · 2026
- Not all light exposure measures are equal: a framework for exposure assessment and causal inference in light epidemiologyBMC Medicine · 2026
- Sensor placement causes outcome-dependent bias in ambulatory light-exposure estimatesbioRxiv · 2026
- Constructing melanopic light exposure profiles from sparse daily-route measurements.Npj biological timing and sleep · 2026
- Cross-validation of wearable light loggers across electric and natural light conditions: focus on illuminance, melanopic EDI, and CCTmedRxiv · 2026
- Impact of wear position on dosimeter performance: measurement validity under simulated indoor illuminationnpj Biological Timing and Sleep · 2026