From the paper's conclusion- We introduce Safety-Focused Evaluation of Scaling (SaFE-Scale) and instantiate it on RadSaFE-200, a 200-question text-based radiology multiple-choice benchmark with clinician-defined clean evidence, conflict evidence, and option-level labels for high-risk error, unsafe answer, and evidence contradiction.
Abstract
Clinical large language models (LLMs) are commonly scaled by increasing model size, context length, retrieval complexity, or inference-time compute, on the assumption that higher accuracy implies safer behavior. In medicine, where a few confident or evidence-contradicting errors can outweigh average performance, this assumption may be incomplete. We introduce Safety-Focused Evaluation of Scaling (SaFE-Scale) and instantiate it on RadSaFE-200, a 200-question text-based radiology multiple-choice benchmark with clinician-defined clean evidence, conflict evidence, and option-level labels for high-risk error, unsafe answer, and evidence contradiction. Thirty-four local LLMs were evaluated across six deployment conditions spanning closed-book, evidence-grounded, standard and agentic retrieval-augmented generation (RAG), and max-context prompting. Clean clinician-written evidence, used as an upper-bound, produced the strongest joint gain, raising mean accuracy from 73.5% to 94.1% and reducing high-risk error from 12.0% to 2.6% and dangerous overconfidence from 8.0% to 1.6%. Standard and agentic RAG, max-context prompting, and inference-time compute improved selected metrics but did not reproduce this safety profile. Clinically consequential errors concentrated in a small subset of questions, and variance decomposition placed deployment condition above model family on every safety metric. Within this evaluation, clinical LLM safety did not track accuracy scaling but emerged as a deployment-level property.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The accuracy-safety trade-off of large reasoning models in clinical diagnostics.Nature communications · 2026
- A novel evaluation benchmark for medical LLMs illuminating safety and effectiveness in clinical domainsnpj Digital Medicine · 2025
- Safeguarding Agentic AI in Radiology Workflows: A Multimodel Evaluation of Rule-based and Large Language Model-based VerificationarXiv · 2026
- A medically grounded LLM agent-based tool to detect patient safety events in medical records.PLOS digital health · 2026
- The Crisis of Ground Truth in Medical AI: Evaluating the Tools Used to Detect LLM HallucinationsInternational Journal for Research in Applied Science and Engineering Technology · 2026
- Clinicians need to review only half of LLM outputs to preserve diagnostic accuracy: the SCOUT randomised crossover trialEuropean Heart Journal · 2026