The influence of surface reflectivity on the accuracy of surface topography mapping with non-contact measurement techniques
Magdalena Niemczewska-Wójcik, Monika Madej, Piotr Nieslony, Grzegorz Krolczyk, Michal Jakubowicz, Michal Wieczorowski
Key points
From the paper's conclusion- The results demonstrate that reflectance, illumination wavelength, and the selected surface parameter must be considered jointly when choosing an optical topography measurement procedure.
Abstract
Surface reflectivity can substantially affect the reliability of non-contact surface topography measurements because optical techniques reconstruct an electromagnetic rather than a mechanical surface. This study investigates the effect of reflectance on surface topography parameters measured on polished AISI 316 L steel specimens, both uncoated and coated with DLC, TiN, TiCN, TiAlN, ZrN, and CrN coatings used in biomedical applications. Surface reflectance and color were determined by spectrophotometry, while topography was measured using coherence scanning interferometry (CSI), imaging confocal microscopy (ICM), focus variation microscopy (FV), and confocal fusion (CF). Contact profilometry was used as the reference method of measurement. The comparison included the Sa, Sq, Sz, Ssk, and Sku parameters and a normalized coefficient of variation, (V_s). The analyzed specimens exhibited reflectance values from (Y = 1.05%) to (Y = 11.12%) in the specular-component-excluded mode. At reflectance values of approximately 10–11%, V s ranged from 0% to 80% for Sa and from 0% to 40% for Sq. For low-reflectance surfaces ((Y = 1.05–2.40%)), unsuitable combinations of optical technique and illumination produced V s values exceeding 200% and, in extreme cases, 1000%. For Sa and Sq measurements within this low-reflectance range, CSI with green or white illumination provided the closest agreement with the contact-reference results. Higher-order parameters were considerably less stable: Sku values obtained from optical measurements exceeded 300–400 in some configurations because of their high sensitivity to noise and isolated surface-reconstruction artifacts. The results demonstrate that reflectance, illumination wavelength, and the selected surface parameter must be considered jointly when choosing an optical topography measurement procedure. This is particularly important for smooth biomedical components with low-reflectance coatings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Uncertainty in surface topographic measurementsSurface Topography: Metrology and Properties · 2026
- A review of error analysis and compensation methods in white-light interferometric surface topography measurementFrontiers in Physics · 2026
- Single-scan structured-illumination dual-modal method for high-completeness micro/nano surface topography measurementSurface Topography: Metrology and Properties · 2026
- From acquisition errors to reliable data: the quantitative-qualitative validation method for surface topography studiesSurface Topography: Metrology and Properties · 2026
- High-Resolution Measurement of Surface Normal Maps Using Specular Reflection Imaging.Journal of imaging · 2026
- Influence of data processing decisions on ISO 25178 areal surface roughness parameters and their relevance to micro-Vickers hardness measurementsSurface Topography: Metrology and Properties · 2026