International journal of gynaecology and obstetrics: the official organ of the International Federation of Gynaecology and Obstetrics

Assessment of fetal head descent and risk of complicated forceps delivery: Role of the suprapubic descent angle.

Shin Hashiramoto, Hiroko Takita, Yusuke Suzuki, Aoi Sekiya, Yuki Mukai, Takeshi Nakamura, Ryu Matsuoka, Akihiko Sekizawa

Department of Obstetrics and Gynecology, Showa Medical University, Tokyo, Japan.

Observational · n=118

Key points

From the paper's conclusion
  • Objective To compare the suprapubic descent angle (SDA) with conventional measures for discriminating complicated forceps delivery and to explore whether discrepancies between SDA‐derived station and conventional fetal station assessments identify higher‐risk cases among women undergoing forceps delivery.

Abstract

OBJECTIVE: To compare the suprapubic descent angle (SDA) with conventional measures for discriminating complicated forceps delivery and to explore whether discrepancies between SDA-derived station and conventional fetal station assessments identify higher-risk cases among women undergoing forceps delivery. METHODS: This prospective cohort included consecutive women with term, singleton, cephalic fetuses in occiput anterior position undergoing forceps delivery at a single tertiary center in Japan during 2025. Before forceps application, SDA, transperineal ultrasound station, angle of progression, head direction, and digital station were assessed. Complicated forceps delivery comprised ≥3 traction attempts, failed forceps requiring cesarean delivery, obstetric anal sphincter injury (OASI), blood loss >1500 g, or significant neonatal trauma. Receiver operating characteristic curves assessed discrimination. Internal validation used 2000 participant-level bootstrap samples, repeating regression fitting and Youden cutoff selection. Sensitivity analysis excluding OASI from the composite outcome was also conducted. RESULTS: Among 118 women, 23 (19.5%) experienced the composite outcome. SDA showed the highest area under the curve (AUC) among individual measures (0.765; 95% confidence interval, 0.641-0.890). The discrepancy between digital station and SDA-derived station had an apparent AUC of 0.838 and an optimism-corrected AUC of 0.836. Apparent sensitivity and specificity at the data-derived cutoff were 69.6% and 91.6%; corresponding optimism-corrected estimates were 64.8% and 90.5%. Excluding OASI left 12 events; the apparent and optimism-corrected AUCs were 0.880 and 0.879. CONCLUSIONS: The SDA and the discrepancy between digital station and SDA-derived station showed promising discrimination of complicated forceps delivery. External validation is required before clinical application or recommendation of a cutoff.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Assessment of fetal head descent and risk of complicated forceps delivery: Role of the suprapubic descent angle — Science Skim