Preliminary evaluation of inductive current transformers applicability for accurate transformation of distorted current
Michał Kaczmarek, Sławomir Wiak, Paolo Di Barba
Key points
From the paper's conclusion- The essence of the accurate transformation of distorted current by the inductive current transformer is to ensure lowest possible self-generation of higher harmonics to its secondary current.
Abstract
In this paper the key idea is presented to assess the applicability of inductive current transformer for transformation of distorted current on the basis of the level of the secondary voltage distortion measured for supplied excitation current of its magnetic core in the no-load state. The RMS value of the main component of the excitation current is determined from measured values of current error and phase displacement in routine test performed in accordance with the standard IEC 61869-2 for transformation of sinusoidal current of a given RMS value with a particular load of the secondary winding. The essence of the accurate transformation of distorted current by the inductive current transformer is to ensure lowest possible self-generation of higher harmonics to its secondary current. This phenomenon is caused by the nonlinearity of the magnetization characteristic of the magnetic core. This method therefore allows the degree of that nonlinearity to be assessed indirectly. For the tested units the factor ranked the operating points in the same order as the self-distortion current error measured in the full distorted-current test whenever the compared values differed by more than 25%. The verification covers only the 3rd and 5th harmonics.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A High-Sensitivity Magnetic Protection Method for Reactors Based on Statistical Testing of Linear Regression ResidualsEnergies · 2026
- High-current regulation system based on an inductance with local saturations: design of the specific DC commandCOMPEL The International Journal for Computation and Mathematics in Electrical and Electronic Engineering · 2026
- A 1D CNN with Exact Grouped SHAP Attribution for Transformer Magnetizing Inrush IdentificationEnergies · 2026
- A 1 kV Compensation-Free Three-Stage Inductive Voltage Divider with Integrated-Reference Self-Calibration.Sensors (Basel, Switzerland) · 2026
- Study on DC biased characteristics of electrical steel using a Preisach model and excitation current validation in transformerAIP Advances · 2026
- Transmission Error Compensation for Industrial Robots Using Fourier SeriesarXiv · 2026