Study on DC biased characteristics of electrical steel using a Preisach model and excitation current validation in transformer
Ziyuan Xin, Dezhi Chen, Haonan Bai, Xianghui Chang, Yun Sun, Sijun Wang
Key points
From the paper's conclusion- The results demonstrate that the proposed Preisach model can effectively reproduce DC bias induced operating-point shift, asymmetric saturation, and excitation-current distortion at the transformer level.
Abstract
Direct current (DC) intrusion through the transformer neutral introduces a DC component into the excitation branch, resulting in flux offset, asymmetric magnetizing current, and an increased risk of local core saturation. These effects distort the no-load current, increase low-order harmonic components, and may further increase losses, heating, vibration, and noise. This paper proposes a hybrid hysteresis modeling method that integrates a Preisach framework with a neural-network-based parameter identification scheme to describe the magnetic behavior of transformer core material under DC bias. A DC biased Preisach model is formulated to account for the nonlinear interaction between AC flux and the DC offset. The magnetic and magnetostrictive properties of 30ZH120 grain-oriented electrical steel are measured under different DC bias levels, providing B–H and B–λ characteristics for model identification. The DC biased B–H characteristics reconstructed by the proposed Preisach model are then introduced into a field and circuit coupled transformer model as a nonlinear magnetic input. Excitation-current simulations and no-load tests are carried out on a 160 kVA single-phase four-limb prototype transformer. The simulated excitation current increases from 1.32 to 4.21 A when the DC component increases from 0 to 0.6 A, while the measured current increases from 1.46 to 4.61 A, with relative errors of 9.59% and 8.68%, respectively. Harmonic analysis further shows that DC bias enhances waveform asymmetry and low-order harmonic components. The results demonstrate that the proposed Preisach model can effectively reproduce DC bias induced operating-point shift, asymmetric saturation, and excitation-current distortion at the transformer level.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Hybrid Jiles-Atherton-Sablik Physics-Informed Convolutional Recurrent Residual Network for Magneto-Mechanical Hysteresis Prediction in Non-Oriented Electrical Steel Fe3%Si.Materials (Basel, Switzerland) · 2026
- Stray Losses in Power Transformers: A Comparative Study of Modeling Frameworks for Mild SteelarXiv · 2026
- Study on the vibration mechanism of medium-high frequency transformers considering core anisotropyAIP Advances · 2026
- A Physics-Informed Neural Network with Hybrid Architecture for Magnetic Core Loss Prediction Under Complex ConditionsMagnetochemistry · 2026
- High-Frequency Transformer Modeling: Methods, Parameter Extraction and Validation—A ReviewEnergies · 2026
- Transformer-guided Variable Projection for Phasor and Fault-Time Estimation Under DDC OffsetarXiv · 2026