Design and development of a full-scale oxygenator model for future biohybrid lung application
Abhishek Singh, Kai Janning, Dio Putra Simbolon, Foivos Leonidas Mouzakis, Ali Kashefi, Khosrow Mottaghy, Michael Neidlin, Ruth Olmer,
Key points
From the paper's conclusion- While gas transfer requires improvement before clinical applicability for extracorporeal CO 2 removal, the fabrication approach provides a foundation for future endothelialization and development of long-term biohybrid lung support devices.
Abstract
Use of conventional oxygenators is typically limited to 10–14 days due to poor hemocompatibility. Endothelialization of gas exchange membranes can create a natural non-thrombogenic surface and has proven effective in small laboratory models, but this approach requires a specific oxygenator design that can support both effective gas exchange and future membrane endothelialization. Thus, we developed a modular spiral-coil oxygenator using a fabrication approach that enables the production of a large membrane surface area with integrated blood channels. We designed and fabricated multiple oxygenator prototypes using a rolled flat-sheet PDMS/spacer/PDMS membrane structure and evaluated their gas exchange and fluid flow. Prototypes were tested for gas exchange performance following ISO 7199:2016 standards. Computational fluid dynamics (CFD) simulations were performed to assess flow distribution and wall shear stress (WSS). Among the tested prototypes, two designs provided the most promising results. They achieved surface areas of 0.20 m² and 0.34 m² with priming volumes of 348 mL and 312 mL, respectively. Both models showed quantifiable gas exchange supporting the feasibility of the proposed concept. CFD simulations revealed no stagnant areas and low WSS. These results demonstrate the feasibility of a modular spiral-coil oxygenator with a large-area flat-sheet membrane and millimeter-scale blood channels. While gas transfer requires improvement before clinical applicability for extracorporeal CO 2 removal, the fabrication approach provides a foundation for future endothelialization and development of long-term biohybrid lung support devices.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Novel Extracorporeal Membrane Oxygenation System With Enhanced Hemocompatibility and Long-Term Stability.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2026
- Laser micro drilled glass semipermeable membranes for microfluidic blood oxygenatorsScientific Reports · 2026
- The Effects of Hollow Fiber Membrane Configuration on Hemodynamic Characteristics, Oxygen Transfer Performance and Thrombosis Risk in Oxygenators: A Numerical Research.Artificial organs · 2026
- Oxygenator deterioration in a standardized in vitro setup: pressure drop, CT-based clot burden, and hemolysisCurrent Directions in Biomedical Engineering · 2026
- Comparative Performance of Oxygenators for Extracorporeal Membrane Oxygenation in Adults: A Retrospective Analysis.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2026
- A multimodal strategy for assessing oxygenator degradation during extracorporeal membrane oxygenation (ECMO): an in vitro evaluationat - Automatisierungstechnik · 2026