Comparative assessment of measurement uncertainty for ICP-MS determination of platinum and palladium in ore using tolerance intervals and ISO 11352
Lamia Zaari Lambarki, Ridouan El Hajji, Wafaa El-Ghaly, Taha El Kamli, Mohamed Bourass, Bouchaib Ihssane, Fadil Bakkali, Taoufiq Saffaj,
Key points
From the paper's conclusion- These findings confirm that the uncertainty profile approach constitutes a practical and resource-efficient alternative to ISO 11352 for laboratories involved in platinum-group element analysis, enabling simultaneous method validation and uncertainty characterization from a single experimental dataset.
Abstract
Accurate determination of platinum (Pt) and palladium (Pd) in ore matrices remains analytically challenging due to matrix complexity, spectral interferences, and the ultra-trace concentrations at which these elements naturally occur. This work presents the development and full validation of an inductively coupled plasma mass spectrometry (ICP-MS) method for the simultaneous quantification of Pt and Pd in ore samples, using lead fire assay with cupellation as the preconcentration step. Validation was performed using a β-content, γ-confidence tolerance interval strategy, which integrates method validation and measurement uncertainty estimation into a single coherent framework, without requiring additional experimental data beyond routine validation work. A simple linear regression calibration model was selected based on systematic evaluation of uncertainty profiles across the working concentration range. Trueness, expressed as relative bias, did not exceed − 2.03% for either element at any concentration level, and recovery was within the predefined acceptance criteria of ± 15%. Measurement uncertainty was subsequently assessed using two complementary top-down approaches: the uncertainty profile method and the ISO 11352 framework. Statistical comparison by Fisher’s F-test demonstrated that the two approaches yield statistically equivalent uncertainty estimates when the proportion β is set to 90% or 95%, establishing this threshold as the minimum requirement for reliable prediction of routine analytical performance from validation data. These findings confirm that the uncertainty profile approach constitutes a practical and resource-efficient alternative to ISO 11352 for laboratories involved in platinum-group element analysis, enabling simultaneous method validation and uncertainty characterization from a single experimental dataset.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Combined LA-ICP-MS with empirical coefficient correction and Bi fire assay for the determination of ultra-trace Pt, Pd, and Au in geochemical samples using a 194Pt isotope spike as the internal standard.Analytical methods : advancing methods and applications · 2026
- Fire Assay and Digestion Strategies for Platinum‐Group Elements, Rhenium and Gold in Geological Materials: A Review of Matrix‐Dependent Workflows and Os Isotope ApplicationsGeostandards and Geoanalytical Research · 2026
- Analytical Validation of a Multielement ICP-MS Method for Human Serum and Its Application to Trace Element Biomonitoring in Hemodialysis Patients.Toxics · 2026
- Proficiency Testing in Geoanalysis: What 30 Years of GeoPT Reveal About Persistent Pitfalls in Metallurgical Laboratories—and How to Fix ThemBHM Berg- und Hüttenmännische Monatshefte · 2026
- Global homogeneity index: An integrated approach for assessing multielement homogeneity in reference materials.Talanta · 2026
- Rapid determination of Ru, Rh, Pd, Ir, and Pt in rock samples using ICP-MS following microwave digestion.Talanta · 2026