Green stability-indicating RP-HPLC method for simultaneous bioanalysis of tedizolid phosphate and ciprofloxacin in human plasma.
Gehad Abd El-Fatah, Amr M Mahmoud, Alaa A Ahmed-Anwar, Ahmed A Farghali, Rehab Mahmoud, Mohamed E M Hassouna
Chemistry Department, Faculty of Science, Beni-Suef University, Beni-Suef, 62514, Egypt. · Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, El-Kasr El-Aini Street, Cairo, 11562, Egypt.
Key points
From the paper's conclusion- Overall, the developed approach presents a rapid, highly accurate, and environmentally sustainable strategy for the simultaneous bioanalysis of TP and CIP in bulk drugs, pharmaceutical formulations, and human plasma.
Abstract
Tedizolid phosphate (TP) and ciprofloxacin (CIP) represent orally effective antibiotics that are often administered in combination for hospitalized patients with complicated or mixed infections, aiming to provide wide antimicrobial coverage. This study describes, for the first time, the establishment of an environmentally sustainable reversed-phase HPLC approach for the simultaneous bioanalysis of TP and CIP in human plasma. The developed chromatographic method allowed for rapid separation within 4 min employing a methanol-water mobile phase, thereby reducing solvent consumption and improving environmental sustainability. The method was validated according to the validation parameters investigated in the present study, with reference to the US FDA Bioanalytical Method Validation Guidance. Excellent linearity was achieved over concentration ranges of 5-90 µg/mL (TP) and 5-80 µg/mL (CIP) in pure samples, and 0.5-30 µg/mL (TP) and 0.5-10 µg/mL (CIP) in human plasma. LOD/LOQ values were 1.60/4.86 µg/mL for TP and 1.58/4.78 µg/mL for CIP in pure samples, and 0.16/0.49 µg/mL for TP and 0.10/0.31 µg/mL for CIP in spiked human plasma. The proposed method was characterized by adequate sensitivity and demonstrated strong performance in terms of accuracy, precision, specificity, and robustness. Furthermore, it proved effective in assessing the forced degradation of TP and CIP under diverse stress conditions, confirming its capability as a stability-indicating approach. The environmental impact of the method was comprehensively evaluated using multiple established greenness and blueness assessment tools, confirming its favorable environmental profile. Overall, the developed approach presents a rapid, highly accurate, and environmentally sustainable strategy for the simultaneous bioanalysis of TP and CIP in bulk drugs, pharmaceutical formulations, and human plasma.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Simplifying the simultaneous bioanalysis of chlorzoxazone and ketoprofen in plasma using salting-out-assisted HPTLC-densitometry with comparative multi-metric sustainability assessment.Journal of chromatography. A · 2026
- Ecologically conscious profiles assessments for economic, and concurrent HPLC detection of chlordiazepoxide and clidinium bromide in bulk and tablets solid dosage formResults in Chemistry · 2025
- Stability indicating HPTLC method for simultaneous analysis of sitagliptin phosphate monohydrate and pioglitazone hydrochloride with greenness assessment using AGREE, ESA, BAGI and CACIDiscover Chemistry. · 2026
- Spectrum meets sustainability: green-validated novel simultaneous assays of antimicrobial fixed dose combination.BMC chemistry · 2026
- Sustainable UHPLC-MS/MS assay for ultra-sensitive simultaneous quantification of amoxicillin and flucloxacillin with application to a bioequivalence study.Analytical and bioanalytical chemistry · 2026
- Simple and cost-effective UV spectrophotometric platforms integrating advanced green and blue metrics for concurrent analysis of dapagliflozin and vildagliptin in diabetes therapyScientific Reports · 2026