On the accuracy of nonlinear image registration in portable low-field 3D brain MRI.
J Eugenio Iglesias, Ian P Johnson, Jonathan Williams-Ramirez, Dina Zemlyanker, Lin Tian, Karthik Gopinath, Mark Olchanyi, Ava D Farnan,
Martinos Center for Biomedical Imaging, Mass General Brigham and Harvard Medical School, Boston, MA 02114 USA. · Center for Brain and Mind Health, Departments of Neurology and Neurosurgery, Yale School of Medicine, New Haven, CT 06510 USA.
Key points
From the paper's conclusion- Overall, existing algorithms can accommodate resolution limitations, however, future methods could further enhance coregistration by explicitly addressing the distortions present in low-field MRI scans.
Abstract
Portable low-field MRI offers an affordable and mobile alternative to conventional high-field scanners, enabling imaging in point-of-care and resource-limited settings. However, its lower signal-to-noise ratio, reduced resolution, and acquisition artifacts raise concerns about the accuracy of standard image registration methods. Reliable nonlinear registration is critical for a wide range of emerging applications, including frequent brain monitoring, assessment of neurodegenerative disease progression, and evaluation of treatment effects such as those associated with Alzheimer's therapeutics. In this work, we systematically evaluated state-of-the-art registration approaches on simulated low-field scans (obtained by downsampling high-field images) and on real low-field brain MRI data. We compared three approaches that are representative of current registration methods: classical optimization (NiftyReg), learning-based registration (SynthMorph), and synthesis-based registration (SynthSR+NiftyReg). Using downsampled high-field scans, all methods performed well, achieving high Dice scores and smooth deformation fields, indicating that reduced resolution alone does not hinder registration. In contrast, real low-field data exhibited lower accuracy, primarily due to geometric distortion and other acquisition-specific artifacts. Among the tested approaches, the synthesis-based pipeline achieved the most robust performance across subjects and modalities. Overall, existing algorithms can accommodate resolution limitations, however, future methods could further enhance coregistration by explicitly addressing the distortions present in low-field MRI scans.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Deep learning super-resolution of paediatric ultra-low-field MRI without paired high-field scans.Scientific reports · 2026
- Diffusion Tensor MRI and Spherical‐Deconvolution‐Based Tractography on an Ultra‐Low Field Portable MRI SystemHuman Brain Mapping · 2026
- Optimization of nested U-Net-based noise reduction for low-field brain MRI: effects of pruning level and patient postureFrontiers in Neuroscience · 2026
- Deep learning-based image domain reconstruction of undersampled low-field brain MRI: A comparative benchmark study of U-Net architectures.Magnetic resonance imaging · 2026
- Repeatable tract-based diffusion metrics on a portable 64 mT MRI: a foundation for global population neuroscience.Frontiers in neuroimaging · 2026
- Low-field and portable MRI technology: advancements and innovationsEuropean Radiology Experimental · 2025