Scientific reports

Energy performance optimization of BIPV windows in dust-prone semi-arid climates.

Isra Shorsh Muhammed, Salahaddin Yasin Baper

College of Engineering, Salahaddin University-Erbil, Erbil, Iraq. isra.muhammed19@yahoo.com. · College of Engineering, Salahaddin University-Erbil, Erbil, Iraq.

Key points

From the paper's conclusion
  • These findings show that the performance of BIPV windows in dusty semi-arid environments can be significantly enhanced by means of the design of the secondary-layer at the facade, rather than photovoltaic integration alone.

Abstract

Dust accumulation remains a persistent constraint on the energy performance and durability of building-integrated photovoltaic (BIPV) windows in semi-arid environments. This paper assesses a facade-scale system of enhancing the operation of BIPV glazing in dusty and high-irradiance climates by introducing interventions of secondary-layers with protective, optical, thermal, and anti-soiling capabilities. The Smart Health Tower has been chosen as a case study in Sulaymaniyah, and a digital workflow was created with Rhino, Grasshopper, Ladybug, and PVsyst to evaluate the current used system and an extended full-façade baseline. As-built upper-window BIPV installation was initially used in tool-to-reality validation with the simulated annual electricity production of 321,685 kWh/year against the reported 321,000 kWh/year with is a deviation of + 0.21. After validation, the model was then extended to a complete-facade BIPV system featuring an active photovoltaic area of 5,814.6 m². The established no-layer monocrystalline baseline generated 2,478,305 kWh/year and the retained annual improvement were: optical film layer 3.0%, anti-UV/anti-scratch layer 5.8%, modular design logic 6.0%, thermal-resistant layer 8.0%, and hydrophobic coating 13.0%. The LSC based concentrating layer had the greatest projected output, 3,543,974 kWh/year, which is equal to a 43.0% increase over the baseline. These findings show that the performance of BIPV windows in dusty semi-arid environments can be significantly enhanced by means of the design of the secondary-layer at the facade, rather than photovoltaic integration alone. Simultaneously, the research identifies that the baseline case was explicitly validated, but the secondary-layer cases were modelled as literature-based comparative projections, rather completely resolved optical-thermal models. In general, the research adds a facade-based approach to the methodology of improving the energy efficiency of BIPV windows in semi-arid urban environments prone to dust.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Energy performance optimization of BIPV windows in dust-prone semi-arid climates — Science Skim