Ultrasound-guided skeletal muscle biopsy technique permits measurement of structural, functional, cellular and biochemical properties
Addison Barber, Amber Willbanks, Guadalupe Meza, Jeremie L. A. Ferey, Gretchen A. Meyer, Sudarshan Dayanidhi, W. David Arnold, Richard L. Lieber,
Shirley Ryan AbilityLab · Washington University in St. Louis
Key points
From the paper's conclusion- The procedure was well tolerated, with an average immediate pain rating of 1.5 ± 1 (range:0–4, scale: 0–10) and 24-hour follow-up rating of 1.7 ± 1 (range:0–4).
Abstract
Human muscle biopsies are often required to study or diagnose diseases. However, traditional approaches are challenging due to limited sample size, quality, or participant discomfort. Fine-gauge needle biopsies (≥ 14-gauge), present an alternative but may yield insufficient tissue for comprehensive analysis. Ultrasound guidance, coupled with vacuum-assisted, single needle-insertion multiple sampling addresses these challenges. In 19 healthy participants (mean age: 30.1 ± 10 years, 42% male), 2–3 samples were collected from a single needle insertion into the vastus lateralis (VL) and tibialis anterior (TA). Summed VL and TA sample masses averaged 148 ± 38 mg and 166 ± 64 mg, with dimensions of 15.83 ± 8 × 2.9 ± 0.6mm 2 (VL) and 15.07 ± 7 × 3.1 ± 0.9mm 2 (TA). VL had a mean fiber cross-sectional area of 4,347 ± 1,931µm 2 , with 221 ± 86 fibers quantified. Samples were of sufficient size and quality for thorough analyses from a single biopsy procedure, including mitochondrial respirometry, RT-PCR, collagen content, and biomechanical function. Fibers produced typical isometric stress values of 187 kPa with a passive modulus of 239 kPa (peak) and 79 kPa (stress-relaxed). The procedure was well tolerated, with an average immediate pain rating of 1.5 ± 1 (range:0–4, scale: 0–10) and 24-hour follow-up rating of 1.7 ± 1 (range:0–4). This report describes an approach that yields high-quality muscle samples suitable for histological and biochemical analyses while minimizing discomfort.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Optimising muscle biopsy: ultrasound-guided technique for enhanced accuracy and safety.Clinical and experimental rheumatology · 2026
- Direct measurement of motor unit twitch properties using routine clinical ultrasound and optical flowmedRxiv · 2026
- Muscle ultrasound for nutrition assessment: Practical clinical protocols.Nutrition in clinical practice : official publication of the American Society for Parenteral and Enteral Nutrition · 2026
- Diagnostic Value of Muscle Biopsy for the Evaluation of Adult Myopathy in Daily Clinical PracticeDiagnostics · 2025
- Surface electromyography-based assessment of upper-limb muscle strength, endurance, and muscle quality during graded handgrip tasks in healthy adults.Technology and health care : official journal of the European Society for Engineering and Medicine · 2026
- Multimodal Phenotyping of Myofascial Pain Syndrome Using Rotational Shear Wave Elastography and Clinical Network Analysis.medRxiv : the preprint server for health sciences · 2026