Long-term outcomes of a novel non-haptic exposure technique for sutureless, glueless intrascleral fixation of a 3-piece intraocular lens: a single surgeon series of 553 eyes.
Pawan Puneet Malhotra, Vipin Rana, Alok Sen, Ritika Chauhan, Amanpreet Kaur, Gurmeet Singh Mangat
Department of Ophthalmology, Sohana Multi-superspecilaty Hospital, Mohali, Punjab, India. drpuneetavm@gmail.com. · Department of Ophthalmology, INHS Asvini, Mumbai, India.
Key points
From the paper's conclusion- The non-haptic exposure technique for sutureless, glueless intrascleral fixation of a 3-piece IOL provided favourable long-term visual outcomes with a low incidence of postoperative complications in eyes with inadequate capsular support. The absence of haptic extrusion and scleral erosion throughout follow up supports the long-term stability of this technique.
Abstract
BACKGROUND/OBJECTIVES: To evaluate the long-term outcomes of a novel non-haptic exposure technique for sutureless, glueless intrascleral fixation of a 3-piece intraocular lens (IOL) in eyes with inadequate capsular support. SUBJECTS/METHODS: This study included 553 eyes of 524 consecutive patients who underwent the non-haptic exposure technique for sutureless, glueless intrascleral fixation of a 3-piece IOL between June 2017 and June 2025. Eyes with active inflammation, uncontrolled glaucoma, severe corneal opacity, or follow up of less than 6 months were excluded. The primary outcome was final best corrected visual acuity (BCVA). Secondary outcomes included uncorrected visual acuity (UCVA) and postoperative complications. Subgroup analysis compared surgical aphakia following cataract surgery (Group A) with other secondary aetiologies (Group B). RESULTS: Mean BCVA improved from 0.60 to 0.20 logMAR (p = 0.002). Mean UCVA improved from 1.47 (SD 0.64) to 0.35 (SD 0.36) logMAR (p < 0.001), with 77% of eyes achieving a final visual acuity of 0.48 logMAR or better. Late postoperative complications included cystoid macular oedema (6.7%), retinal detachment (2.9%), and IOL subluxation (2.2%). Retinal detachment occurred more frequently in Group B than in Group A (p = 0.039). No eye developed haptic extrusion, scleral erosion, or acute endophthalmitis during follow up. CONCLUSIONS: The non-haptic exposure technique for sutureless, glueless intrascleral fixation of a 3-piece IOL provided favourable long-term visual outcomes with a low incidence of postoperative complications in eyes with inadequate capsular support. The absence of haptic extrusion and scleral erosion throughout follow up supports the long-term stability of this technique.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Haptic-Extended Flange Intrascleral Fixation for Single-Piece Acrylic Intraocular Lenses.Journal of clinical medicine · 2026
- Extraocularly Manipulated Flangeless Intrascleral Haptic Fixation of Intraocular Lens Using Zigzag Needles.Cureus · 2026
- Scleral suture fixation of a foldable intraocular lens without a scleral flap or groove.Romanian journal of ophthalmology · 2026
- Sutureless Scleral Fixated Intraocular Lens Implantation Techniques: Evolution, Innovations, and OutcomesSurgical Techniques Development · 2026
- Clinical outcomes of repositioning subluxated in-the-bag intraocular lenses using the flanged belt-loop technique with 6-0 polypropyleneJournal of Cataract & Refractive Surgery · 2025
- Flanged Polypropylene Suture for Preset One-Piece Acrylic Intraocular Lens Fixation with Pre-Threaded Needle Technique: Surgical Technique and Short-Term Clinical Outcomes.Clinical ophthalmology (Auckland, N.Z.) · 2026