Pediatric research

Relationship between intra-thoracic pressure, lung volume and high-frequency jet ventilation in lungs predisposed to gas trapping: an animal study.

Lucy Loft, Risha Bhatia, Peter M Loughnan, David G Tingay

Neonatal Research, Murdoch Children's Research Institute, Parkville, VIC, Australia. · Neonatal Research, Murdoch Children's Research Institute, Parkville, VIC, Australia. david.tingay@mcri.edu.au.

Preclinical

Key points

From the paper's conclusion
  • Electrical impedance tomography was able to identify optimal lung volume, which may be useful in titrating the best high-frequency jet ventilation rate between 240 and 400 bpm for carbon dioxide clearance.

Abstract

High-frequency jet ventilation (HFJV) is used to manage severe respiratory failure in neonates, especially to manage gas trapping. To our knowledge, the role of HFJV rate on lung volume states and intra-tracheal and thoracic pressures has not been described. The aim of our study was to determine the impact of HFJV rate (HFJVrate) on (1) total and regional end-expiratory lung volume (EELV) and (2) intra-thoracic pressure, specifically intra-tracheal pressure (Ptrach) and oesophageal pressure (Poes) in adult New Zealand white rabbits (n = 5) prone to gas trapping. After stabilisation on HFJV (Bunnell LifePulse Ventilator; mean (SD) PEEP and HFJV PIP were 5.6 (1.3) cmH2O and 21 (2.6) cmH2O), HFJVrate between 150 and 900 bpm were randomly applied and regional EELV (electrical impedance tomography), Ptrach and Poes measured with gas exchange parameters. The non-gravity-dependent hemithorax demonstrated greater relative EELV with increasing HFJVrate, suggesting overdistension at higher rates. ΔPtrach increased linearly from HFJVrate 150 to 900 bpm and conversely ΔPoes was more variable, decreased with increasing HFJVrate. There was a U-shaped relationship between HFJVrate and PaCO2 with best CO2 clearance occurring at HFJVrate 320-400 bpm. IMPACT: In an animal model susceptible to gas trapping, high-frequency jet ventilation rate influenced volume state with increased carbon dioxide at low and high rates. This is the first study to define the mechanisms by which expiratory time during high-frequency jet ventilation alone can cause and relieve overdistension and atelectasis. Electrical impedance tomography was able to identify optimal lung volume, which may be useful in titrating the best high-frequency jet ventilation rate between 240 and 400 bpm for carbon dioxide clearance.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers