  • Utilizing picosecond infrared laser mass spectrometry (PIRL-MS), we set out to determine the limit of tumor infiltration detection offered by this ambient ion source.

Abstract

Utilizing picosecond infrared laser mass spectrometry (PIRL-MS), we set out to determine the limit of tumor infiltration detection offered by this ambient ion source. Using murine models of brain cancer subjected to handheld PIRL-MS, as well as spatially resolved PIRL-MS imaging and various tissue models, we estimated the limit of tumor infiltration detection to be approximately 15% using physically combined glioblastoma tissue sections and approximately 4% using computational pixel mixing of orthotopic medulloblastoma imaging data. These estimates are broadly consistent in magnitude with independent iKnife-REIMS studies that employed different sampling methods and experimental models. At these detection limits, PIRL-MS predicted positive margins with a sensitivity of 84.21% and a specificity of 86.43%. This observation is based on the analysis of n = 38 orthotopic glioblastoma murine tissue sections bearing various tumor ranges and utilized n = 178 classifiable mass spectral data points. As a proof-of-principle study, these estimates derive from a limited number of biological replicates, including n = 3 subcutaneous xenografts used to construct the tissue model, n = 5 orthotopic animals for validation, and n = 2 tumors underlying the imaging-based estimate and, therefore, should be regarded as preliminary rather than definitive detection limits. These findings highlight the potential of PIRL-MS as a rapid, label-free intraoperative tool for margin assessment and provide insight into the practical limits of tumor infiltration detection in heterogeneous brain tumors.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Assessing the Limit of Tumor Infiltration Detection Using Averaged Mass Spectra from a Handheld Picosecond Infrared Laser Mass Spectrometry Probe: A Proof-of-Principle Study — Science Skim