Assembly-Improved Dye-Quenching Efficiency Enables High-Contrast Activatable Nanoreporters with Multimodal Readouts.
Maochao Zheng, Fei Li, Jialong Sun, Shanshan Meng, Zhen Li, Keyang Li, Jun Zhu, Dan Zhang,
State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Innovation Laboratory for Sciences and Technologies of Energy Materials of Fujian Province (IKKEM), Xiamen University, Xiamen361005, China. · State Key Laboratory of Vaccines for Infectious Diseases, Xiang an Biomedicine Laboratory, Xiamen University, Xiamen361005, China.
Key points
From the paper's conclusion- Together, AIDE establishes a generalizable framework for high-contrast, multimodal, and minimally invasive disease diagnostics.
Abstract
Precise optical signal regulation is essential for diagnostic tools; however, most existing systems suffer from inefficient off-state quenching due to limited control over intermolecular interactions and are often constrained by single-modality outputs. Herein, we introduce a self-assembly guided quenching framework, termed Assembly-Improved Dye-quenching Efficiency (AIDE), which integrates Förster resonance energy transfer (FRET) and aggregation-caused quenching (ACQ) within a cooperative nanoscale architecture to enhance off-state suppression. As a representative implementation, AIDE is realized using tin(IV) naphthalocyanine (SnPc), a near-infrared chromophore with a high extinction coefficient and strong aggregation propensity. When combined with infrared fluorophores, SnPc functions as both a FRET acceptor and an ACQ scaffold, enabling near-complete fluorescence suppression (>99%) through assembly-dependent energy dissipation beyond conventional molecular designs. By introducing biomarker-cleavable linkers, we construct single-stimulus, dual-responsive multimodal nanoreporters (SDMRs) that integrate near-infrared fluorescence, photoacoustic imaging, and renal-clearable urinary readouts upon activation, thereby extending output signal wavelengths and expanding quencher functionality. Notably, SDMRs exhibit intrinsic tropism for inflamed tissues. In rodent models, this trimodal platform enables early detection of tumors (∼6 mm) and skin allograft rejection (24 h post-transplantation). Together, AIDE establishes a generalizable framework for high-contrast, multimodal, and minimally invasive disease diagnostics.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cyanine-Based Near Infrared-II Aggregation-Caused-Quenching Probes for Particokinetic Analysis.Small (Weinheim an der Bergstrasse, Germany) · 2026
- Long ssDNA probe catalytic hairpin assembly cascade reaction based AuNPs aggregation assay for sensitive and colorimetric analysis of anesthesia-induced delirium related microRNA.Analytical methods : advancing methods and applications · 2026
- Donor-Acceptor Bridging via Twisted Quasi-Double-Bond: A Facile Design Strategy for Typical NIR-II AIEgen with "Simple" Structure.Chemical & biomedical imaging · 2026
- Deep Learning-Assisted RTP Sensor Array Based on a Melt-Injection Reaction for Visual Discrimination of Fluoroquinolone Antibiotics.Analytical chemistry · 2026
- Viscosity‐Responsive AIEgen TQ‐A1 for Real‐Time Imaging of Targeted Mitochondrial Fragmentation and Photodynamic Tumor TherapySmall Structures · 2026
- Morphology-Engineered Gold Nanostars for Activatable NIR-II Imaging of Intracellular miR-21 with Deep Tissue Capability.Analytical chemistry · 2026