Chemical & Biomedical ImagingOpen accessElectrochemiluminescence

Versatile Electrochemiluminescence Imaging Platformfor Multiplexed Biosensing and Point-of-Care Application

Stephania Rodríguez Muiña, Gabriele Giagu, Giovanni Valenti, Francisco Javier del Campo

Euskadiko Parke Teknologikoa · University of Bologna

Key points

From the paper's conclusion
  • These results demonstrate the importance of controlled and optimized camera parameters for quantitative ECL imaging and establish this compact, low-cost, and modular platform as a practical alternative for spatially resolved ECL biosensing and multiplex point-of-care applications.

Abstract

Abstract Electrochemiluminescence (ECL) offers high analytical sensitivity, low optical background, and spatially confined light emission at electrode interfaces, enabling a large global market for bead-based ECL immunoassays. Existing ECL instrumentation remains bulky, costly, and largely confined to centralized laboratories with limited access to true spatially resolved imaging. Here, we present a compact, modular ECL imaging platform that enables low-light, spatially resolved, and temporally synchronized electrochemical–optical measurements. The system integrates a Raspberry Pi 4 controller, a monochrome OV9281 global-shutter camera, and an EmStat4s potentiostat, coordinated through open-source Python software providing sub-100 ms synchronization and full control of camera parameters (resolution, exposure, gain, frame rate, and focus). The complete system, of approximately 21 × 15 × 21 cm, has a component bill of materials of 2337 €, which could be reduced to a few hundred euros by using a custom potentiostat, making it substantially more affordable than commercial ECL instruments. Platform performance was validated using both homogeneous solution-phase and heterogeneous bead-based [Ru(bpy)3]2+/tripropylamine (TPrA) assays on carbon screen-printed electrodes. Synchronized cyclic voltammetry and chronoamperometry captured ECL transient behavior, including onset, peak emission, and decay dynamics. Quantitative bead-based assays showed excellent linearity with low-picomolar range limits of detection, while spatially resolved analysis enabled multiplexed measurements on a single electrode via a region-of-interest readout. These results demonstrate the importance of controlled and optimized camera parameters for quantitative ECL imaging and establish this compact, low-cost, and modular platform as a practical alternative for spatially resolved ECL biosensing and multiplex point-of-care applications.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Versatile Electrochemiluminescence Imaging Platformfor Multiplexed Biosensing and Point-of-Care Application — Science Skim