Deep-Learning-Decoded Spatial Electrochemiluminescence from Potentiostat-Free, Button-Battery-Driven Microneedle Arrays for Multiplexed microRNA Imaging.
Pei-Xin Yuan, Mi Chen, Wen Liu, Xue-Li Yang, Ai-Jun Wang, Tiejun Zhao, Jiu-Ju Feng
Key Laboratory of the Ministry of Education for Advanced Catalysis Materials, Zhejiang Key Laboratory of Advanced Catalysis and Adsorption Materials, College of Chemistry and Materials Science, College of Geography and Environmental Sciences, Zhejiang Normal University, Jinhua321004, China. · Department of Neurosurgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei430000, China.
Key points
From the paper's conclusion- A hybrid convolutional neural network (CNN) model decoded spatial emission patterns, extending the linear ranges to 1.28 ∼ 32 fM and 0.59 ∼ 32 fM, beyond those achieved by pixel averaging.
Abstract
Electrochemiluminescence (ECL) bioassays are essential for rapid intracerebral hemorrhage (ICH) diagnosis, while conventional approaches require bulky instrumentation and complex readout electronics that hinder point-of-care (POC) use. To address this limitation, we developed a battery-driven catalysis-initiated ECL imaging platform for multiplexed detection of ICH-associated microRNAs. The device integrated a gold film-modified copper microneedle array (Au film/Cu MNA), polydimethylsiloxane (PDMS) dual-chamber microcells, and button-battery excitation. Heterogeneous catalysis at the Au film/Cu MNA generated reactive oxygen species (ROS) that amplified ECL and sustained luminescence propagation across 168 μm. A competitive hybridization assay using ferrocene-modified linker DNA (Fc-LDNA) on microneedle tips enabled simultaneous miRNA-126 and miRNA-21 detection with detection limits of 4.6 and 0.8 pM, respectively. A hybrid convolutional neural network (CNN) model decoded spatial emission patterns, extending the linear ranges to 1.28 ∼ 32 fM and 0.59 ∼ 32 fM, beyond those achieved by pixel averaging. Preliminary clinical validation (n = 35 ICH, n = 25 healthy controls) revealed an inverse miRNA expression correlation and dual-target diagnostic accuracy (AUC = 0.993), exceeding single-biomarker performance (miRNA-126: AUC = 0.945; miRNA-21: AUC = 0.964). This strategy advances ECL bioanalysis toward portable, multiplexed biomarker quantification in neurological and inflammatory diseases.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Recent Proceedings of Advanced Electrochemiluminescence Imaging Technology and Applications in Accurate AnalysisChemical & Biomedical Imaging · 2025
- Spatiotemporal andDigital ElectrochemiluminescenceImaging for Intelligent Quantitative BiosensingChemical & Biomedical Imaging · 2026
- Versatile Electrochemiluminescence Imaging Platformfor Multiplexed Biosensing and Point-of-Care ApplicationChemical & Biomedical Imaging · 2026
- Hydrogel Microneedle-Integrated Electrochemical Sensor With Negative-Potential Readout Toward Wash-Free and Anti-Interference Monitoring of miRNAs in Tumor Interstitial Fluid.Advanced healthcare materials · 2026
- Electrochemiluminescence Microscopy.Chemical & biomedical imaging · 2026
- Bioinspired Compartmentalization Coupled with DNA-Gated Magnetic Nanoprobes Enables Simultaneous Electrochemical Detection of Dual MicroRNAs.Analytical chemistry · 2026