Optimization of Sensor Response Time in Microfluidics-Based Biosensors with Balanced Analyte Transport
N Muralikrishna, Sayan Das, Somnath Santra, Parikshit Sahatiya, Arnab Guha
Key points
From the paper's conclusion- The findings demonstrate that the combination of block-induced flow-field modifications and auxiliary-inlet-mediated flow confinement effect significantly augments analyte transport to the sensor surface, thereby decreasing the sensor response time by approximately 92% in comparison to the scenario devoid of a block and auxiliary inlet.
Abstract
The combined effect of geometric obstruction and auxiliary inlet on sensor response time for a microfluidics-integrated biosensor has been numerically investigated in this study. The flow behavior and mass transfer of an analyte have been modeled using incompressible Navier–Stokes equations coupled with convection–diffusion and Langmuir adsorption kinetics equations for comparable time scales of diffusion and surface reaction. Introduction of a block increases the analyte velocity near the sensor surface with subsequent reduction in diffusion boundary layer thickness, thereby ameliorating the sensor response time. Insertion of an auxiliary inlet diminishes the sensor response time to a greater extent by confining a thin layer of analyte above the sensor surface. A systematic parametric study is conducted to evaluate the blended effects of block height, block position, block width, auxiliary inlet position, and auxiliary inlet velocity on sensor performance. Taguchi-based optimization techniques employing an L27 orthogonal array alongside signal-to-noise ratio analysis and analysis of variance have been utilized for identification of optimal parameter combinations. The results indicate that the auxiliary inlet velocity is the most influential parameter with a contribution of 65.8% toward the decrement in sensor response time. The findings demonstrate that the combination of block-induced flow-field modifications and auxiliary-inlet-mediated flow confinement effect significantly augments analyte transport to the sensor surface, thereby decreasing the sensor response time by approximately 92% in comparison to the scenario devoid of a block and auxiliary inlet. This study provides valuable insights for the design and optimization of point-of-care microfluidic devices with reduced detection time.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Lab-on-a-chip device with an integrated surface acoustic wave micromixer for enhanced porous silicon biosensor performance.RSC advances · 2026
- Numerical Characterization and Experimental Optimization of Microfluidic DNA Microarray HybridizationDNA · 2026
- Characterizing Variations in Binding Kinetics of Affinity Biosensors: A Boundary-Layer and Site-Quality Approach.ACS omega · 2026
- Unidirectional surface acoustic waves enhance fluid transport and reaction sensitivity in porous nitrocellulose membranes.Lab on a chip · 2026
- Quantitative modeling of on-chip peristaltic pump with air-damped microfluidic deviceJournal of Physics: Conference Series · 2026
- Recent advances in dielectric and two-dimensional material-based surface plasmon resonance biosensors for ultrasensitive refractive index sensing and diverse applicationsAdvanced Optical Technologies · 2026