Rapid Point-of-Care Quantification of Urinary Tract Infection Biomarker Xanthine Oxidase.
Ellen Stadler, Mark Sutton, Colin Brown, Wubbo de Boer, Rahaf Ammouri, Alison Holmes, Timothy M Rawson, Danny O'Hare
Centre for Antimicrobial Optimisation, Imperial College London, W12 0NN London, United Kingdom. · Antimicrobial Discovery, Development and Diagnostics (AD3) UK Health Security Agency, Porton Down SP4 0JG, Salisbury, United Kingdom.
Key points
From the paper's conclusion- We developed a rapid and sensitive point-of-care electrochemical sensor for XO detection by using a simple manufacturing approach.
Abstract
Antimicrobial resistance is a growing global health threat. Overuse of antimicrobial drugs is a main driver of resistance, with urinary tract infections (UTIs) a common indication for antibiotic use. To improve UTI treatment and reduce antimicrobial resistance, real-time diagnostic tools for monitoring the host immune response are needed. Xanthine oxidase (XO) is an enzyme that is elevated in UTIs and shows potential for sensitive and selective detection of infection. We developed a rapid and sensitive point-of-care electrochemical sensor for XO detection by using a simple manufacturing approach. The sensor consists of a disposable carbon electrode embedded in a capillary fill chamber designed for point-of-care sample collection. After urine collection, XO catalyzes its substrate while changing the oxidation state of a secondary electron acceptor. The magnitude and rate of this redox shift reflects XO activity, enabling quantification of XO in urine. We demonstrate minimal intersensor variability of less than 5%, resulting in a calibration with an R 2 of 0.985 across eight individual sensors. The capillary fill device was optimized to enable efficient substrate dissolution, reducing the time to result from 10 min to just 2 min. This approach enables calibration-free detection of XO in artificial and spiked human urine samples within 2 min of sample collection in both artificial urine and spiked human urine samples.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Paper-based colourimetric biosensor for simultaneous detection of UTI-associated nitrite and β-lactamase-mediated resistance using an iodometric method.Enzyme and microbial technology · 2026
- Next-generation point-of-care diagnostics for urinary tract infections: a systematic review of rapid pathogen detection methods.GMS infectious diseases · 2026
- Rapid Bacterial Identification and Antimicrobial Susceptibility Testing Directly from Urine Samples via an Asymmetric Polymerase Chain Reaction-Cas12a PlatformAnalytical Chemistry · 2025
- Evaluating Analytical Performance of Commercial Screen-Printed Electrodes for Point-of-Care Uric Acid Sensing: A Comparative StudyApplied Sciences · 2026
- Nanoparticles in the treatment of urinary tract infections: a comprehensive review.Nanotechnology · 2026
- An automated microfluidic biosensor with bispecific rabbit monoclonal antibody and nanozyme‐bioenzyme composite for dual antibiotic detectionBMEMat · 2025