Analytical Methodology for Sensitive Detection of the Antidepressant Drug Duloxetine in Urine Samples Using Riboflavin-Coated Fe3O4 Magnetic Particles.
Rihab Gargouri, Halil İbrahim Ulusoy, Ümmügülsüm Polat, Erkan Yılmaz, Gökhan Sarp, Ramzi Maalej, Kamel Damak
LaMaCoP, Faculty of Sciences of Sfax, University of Sfax, Sfax 3018, Tunisia. · Department of Analytical Chemistry, Faculty of Pharmacy, Sivas Cumhuriyet University, Sivas 58140, Turkiye.
Key points
From the paper's conclusion- This study presents the development of a novel separation and preconcentration method for the trace-level determination of duloxetine using HPLC-DAD following magnetic solid-phase extraction (MSPE).
Abstract
Antidepressant drugs are widely used and effective in treating mood disorders. Monitoring low concentrations of these drugs in biological samples such as solid tissues and biofluids with high sensitivity is challenging for conventional analysis methods. The present study aims to determine duloxetine molecules at trace levels in urine samples by using a simple sample preparation method and a high-performance liquid chromatography coupled with diode array detection (HPLC-DAD) system. This study presents the development of a novel separation and preconcentration method for the trace-level determination of duloxetine using HPLC-DAD following magnetic solid-phase extraction (MSPE). For this purpose, tetraethyl orthosilicate (TEOS)-coated magnetic nanoparticles functionalized with riboflavin (Fe3O4@TEOS-riboflavin) were synthesized and thoroughly characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), and Fourier-transform infrared (FTIR) spectroscopy. Following MSPE, duloxetine exhibited a linear response over the range of 10.00-800.00 ng·mL-1 (R2: 0.9942). The limits of detection (LOD) and quantification (LOQ) were determined to be 3.28 and 9.60 ng·mL-1, respectively. Relative standard deviations (RSDs) were below 5.1% for triplicate analyses of model solutions containing 100 ng·mL-1 of duloxetine. Moreover, the developed method was successfully applied to both synthetic and healthy human urine samples, providing quantitative results in recovery studies. The recovery values for synthetic and human urine samples ranged from 98.1 to 102.2%, indicating that the combination of MSPE with HPLC-DAD provides a reliable approach for the accurate determination of duloxetine concentrations in urine.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Determination of Antidepressants in Portuguese WastewaterEnvironments · 2026
- Validated Micelle-enhanced Spectrofluorimetric Determination of Serotonin in Human UrineChemical Science International Journal · 2026
- Design of a Molecularly Imprinted Magnetic Micro‐Solid Phase Extraction Sorbent for Sensitive and Selective Determination of Sparfloxacin in Biological FluidsChemistrySelect · 2026
- Frequency-resolved near-infrared photothermal lens spectrometry for simultaneous determination of some antidepressant drugs in human saliva using charge-transfer complexation.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026
- Recent Advances in Sorbent- and Solvent-Based Sample Preparation Techniques for Antidepressant Analysis: Trends, Comparison, and Perspectives.Critical reviews in analytical chemistry · 2026
- First Spectrofluorimetric Determination of Mirogabalin in Biological Fluids: A Validated Hantzsch Derivatization Strategy With Full NMR Structural Confirmation.Luminescence : the journal of biological and chemical luminescence · 2026