Real-Time, Minimally Invasive Oxygen Sensing via Luminescence Loss in Singlet Oxygen-Resistant Triplet-Triplet Annihilation Upconversion Nanocapsules.
Maria Micheva, Yuri Avlasevich, Kerstin Steinbrink, Stanislav Baluschev, Katharina Landfester
Department of Physical Chemistry of Polymers, Max Planck Institute for Polymer Research, Ackermannweg 10, Mainz55128, Germany. · Department of Dermatology, University Hospital Münster, University of Münster, Von-Esmarch-Str. 58, Münster48149, Germany.
Key points
From the paper's conclusion- Here, we introduce a radically new optical sensing strategy for real-time, minimally invasive monitoring of dissolved oxygen in the extracellular aqueous microenvironment.
Abstract
Oxygen concentration in the extracellular microenvironment plays a critical role in regulating metabolism and disease progression, particularly under hypoxic conditions. Here, we introduce a radically new optical sensing strategy for real-time, minimally invasive monitoring of dissolved oxygen in the extracellular aqueous microenvironment. Instead of relying on the oxygen-dependent quenching of phosphorescence or delayed fluorescence lifetimes, which is commonly used in existing sensors, we demonstrate that the local cumulative loss of upconverted fluorescence intensity in triplet-triplet annihilation upconversion (TTA-UC) nanocapsules provides a highly sensitive, one-to-one correspondence with the local oxygen concentration. This method enables an oxygen sensing dynamic range from normoxia (160 mmHg) to deep hypoxia (1.5 mmHg), achieving a detection limit of 45 nM. The sensing platform combines nanoconfined TTA-UC chromophores with sacrificial singlet oxygen scavengers (SSOS) within a hydrophobic nanocapsule core, ensuring complete chemical sequestration of photogenerated singlet oxygen. Furthermore, the use of a hydrophobic surfactant n-octadecyl trimethylammonium chloride (OTAC) minimizes free surfactant in the aqueous phase, drastically reducing cytotoxicity. With excitation intensities as low as 6.6 W cm-2 (λ = 631 nm), radiation stress is kept negligible. Crucially, the method requires no signal averaging, enabling real-time, high-fidelity oxygen monitoring without artifacts from dynamic equilibria. This approach offers a transformative tool for studying oxygen dynamics in living cells and tissues.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Coupled Molecular Crowding and Spatial Confinement Enable Reversible Sensing of Dissolved Chlorine Dioxide.ACS sensors · 2026
- Endogenous Oxygen Depletion-Based Emulsion Polymerization Nanospheres for Room-Temperature Phosphorescence BioimagingACS Nano · 2026
- Tapered hydrogel optical fiber probe for rapid and localized luminescence lifetime-based dissolved oxygen sensing.Optics express · 2026
- Synergistic catalysis of MoC nanoclusters/Co single-atom sites for H₂O₂-free electrochemiluminescence detection of ascorbic acid.Mikrochimica acta · 2026
- Chitosan‑stabilized protein capsules for sustained and reliable chemiluminescent detection of hydrogen peroxide.Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2026
- Microenvironment regulation of ruthenium complexes based on PDMS microsphere carriers and highly sensitive detection of dissolved oxygenFrontiers in Materials · 2026