Coupled Molecular Crowding and Spatial Confinement Enable Reversible Sensing of Dissolved Chlorine Dioxide.
Huisi Li, Simin Lin, Lejie Liu, Hao Bai, Zhouyu Chen, Jiancheng Zhou, Shenghui Zhang, Leyi Lü,
Key Laboratory of Applied Surface and Colloid Chemistry of Ministry of Education, Shaanxi Key Laboratory of New Concept Sensors and Molecular Materials, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an710119, P.R. China. · School of Physics and Information Technology, Shaanxi Normal University, Xi'an710119, P. R. China.
Key points
From the paper's conclusion- These results establish spatial confinement as a means to promote analyte access and activate reversible PET-based fluorescence sensing beyond conventional molecular probe design.
Abstract
Reversible fluorescence sensing of chlorine dioxide (ClO2) is challenging because its strong oxidizing character commonly drives irreversible probe conversion. Here, we show that a porous polymer microenvironment can activate reversible ClO2 sensing in a luminogen that is essentially unresponsive in homogeneous solution. A tripodal o-carborane luminogen, Ph-3Na, was designed to combine molecular crowding with efficient charge-transfer and aggregation-induced emission, affording a 577-fold aggregation-induced fluorescence enhancement and an aggregate-state quantum yield of 47.6%. Immobilization of Ph-3Na within cross-linked porous polystyrene generated a bright sensing material that undergoes pronounced fluorescence attenuation upon exposure to dissolved ClO2 without detectable bulk analyte consumption. Time-resolved fluorescence measurements reveal a shortened excited-state lifetime upon ClO2 exposure, supporting a dynamic-quenching contribution, while calculated frontier-orbital alignment is consistent with a possible photoinduced electron transfer (PET) pathway. The material responds within 45 s over 0.31-20 mg L-1 and retains reversible switching over 150 cycles. Integration into a flow-through device further enables quantitative ClO2 monitoring in environmental and food-disinfection samples. These results establish spatial confinement as a means to promote analyte access and activate reversible PET-based fluorescence sensing beyond conventional molecular probe design.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Dual-mode chemosensor based on oxidative cyclization of 2-hydrazinobenzothiazole functionalized perylene diimide for rapid recognition of HClO in environmental samples and living organisms.Journal of hazardous materials · 2026
- A portable dual‐ratiometric fluorescent and colorimetric probe for ClO − sensing across environmental samples, smartphone platform and cabbageBulletin of the Korean Chemical Society · 2026
- Single-Atom Switching for Constructing a Full-Spectrum Hypochlorite-Responsive Probe Library: Screening Candidates for Water Analysis.Journal of agricultural and food chemistry · 2026
- An oligothiophene-based "turn-on" fluorescent probe: Ultrasensitive detection and bioimaging of hypochlorite in environmental and living systems.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026
- Cucurbit[7]uril-assisted supramolecular fluorescent probe for visualizing the dynamic correlation of HClO and Cys without signal crosstalk in bioimaging.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026
- Rational construction of ratiometric near-infrared fluorescent probe based on flavylium derivatives for detection and imaging of ClO- in plant-water and biological systems.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026