ACS ES&T WaterOpen accessChloramine

Complexity of Chloramine Decay Kinetics in Premise Plumbing

Tolulope Odimayomi, Darel C. Snead, Amy Pruden, Marc Edwards

Vanda Institute

Key points

From the paper's conclusion
  • Here, we carried out complementary experiments in an at-scale premise plumbing rig with mature biofilms (>4 years age) with influent residuals of <0.2, 0.25, 0.5, 1.0, and 2.5 mg/L as Cl 2 and sterile glass jars, with and without an inoculum containing nitrifying bacteria.

Abstract

High Resolution Image Download MS PowerPoint Slide Nitrification-driven chloramine decay kinetics have largely been unquantified in premise plumbing, which is particularly vulnerable to opportunistic pathogen growth. Here, we carried out complementary experiments in an at-scale premise plumbing rig with mature biofilms (>4 years age) with influent residuals of <0.2, 0.25, 0.5, 1.0, and 2.5 mg/L as Cl 2 and sterile glass jars, with and without an inoculum containing nitrifying bacteria. Chloramine decay was complete after 8 h of stagnation in all PEX rig pipes (n = 16), tested over a range of diameters (1/4–3/4”) and flow rates (0.25–2.2 gpm), with decay rates increasing in situations with higher nitrification rates. The jar experiments revealed that chloramine actually persisted better at higher (37–39 °C) than lower (19–30 °C) temperatures, contrary to standard temperature-adjusted kinetic assumptions, presumably because nitrifiers are inhibited at higher temperatures. Contrary to assumptions made in conventional models, chloramine decay was only effectively modeled as first order in 8/24 cases in the rig experiment (R 2 > 0.9). The best fit chloramine decay reaction order varied among the rig pipes from 0.88 to 2.74, depending on chloramine dose and exposure time, hydraulics, and modeling method.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers