Validating a Smartphone-Powered NFC Bipotentiostat to Enable Dual-Working Electrode Measurements for Point-of-Care Electrochemical Biosensing
Rae A. Bellows, Kira L. Rahn, Wyatt C. Hummel, Brian J. Geiss, David S. Dandy, Charles S. Henry
Key points
From the paper's conclusion- Parameters for the chosen potentiostat, the SIC4341 developed by Silicon Craft Technology PLC, were optimized, and comparable electrochemical performance of the NFC bipotentiostat mode and a traditional bipotentiostat was demonstrated.
Abstract
Electrochemical biosensors have emerged as attractive point-of-care testing platforms that provide rapid, quantitative results without expensive, bulky instrumentation. Sensors that use near-field communication (NFC) potentiostats have specifically gained traction because they are low-cost, portable, and battery-free, using a smartphone to passively transfer power and data. While many NFC potentiostat-driven sensors have been developed, these sensors can only measure one working electrode at a time, limiting their usefulness for applications that require detection of multiple analytes. To address this limitation, we demonstrate the first example of an NFC potentiostat used in bipotentiostat mode to achieve dual measurements from two working electrodes in an electrochemical immunoassay. Parameters for the chosen potentiostat, the SIC4341 developed by Silicon Craft Technology PLC, were optimized, and comparable electrochemical performance of the NFC bipotentiostat mode and a traditional bipotentiostat was demonstrated. The NFC bipotentiostat mode was then used to concurrently collect a blank and sample measurement for our previously developed magnetic bead-based electrochemical surrogate virus neutralization test (esVNT). When comparing both the mono-channel and bipotentiostat modes of the NFC and traditional potentiostats, highly similar performance was confirmed, establishing the NFC potentiostat as an important alternative for low-cost and portable point-of-care testing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Near-Field Communication-Enabled Wearable Chemical Sensors for Bioanalytical Monitoring.Chemistry, an Asian journal · 2026
- Capillary-Driven Duplex Microfluidic Device Enabling Simultaneous Electrochemical Immunoassays for Detecting SARS-CoV-2 and Respiratory Syncytial VirusACS Sensors · 2026
- From Bench to Bedside: Clinical Translation of Electrochemical Biosensors for Viral Diagnostics.Diagnostics (Basel, Switzerland) · 2026
- Biochemical Interface Engineering for Transistor-Based Point-of-Care DiagnosticsAccounts of Chemical Research · 2026
- Smartphone-connected, battery-free aptamer-based digital test for quantification of procalcitonin and monitoring of infection at the point of caremedRxiv · 2026
- Boron-Nitride-Doped Graphene Oxide FETs for COVID-19 Detection: A Comparative Review Against Existing Market Solutions.Materials (Basel, Switzerland) · 2026