ACS Applied Polymer Materials

Distinguishing Reversible Plasticization and Irreversible Degradation in Polymeric Liners

Mohammadjavad Haji Rezaei, Deepro Ghosh, Keven Alkhoury, Zakhar Lyakhovych, Edith Mathiowitz, Vikas Srivastava, Ryan Poling-Skutvik

Key points

From the paper's conclusion
  • These results demonstrate that viscoelastic measurements can distinguish between reversible and irreversible degradation processes that may not be detected by conventional measurements.

Abstract

Polymeric materials are increasingly used in natural gas infrastructure, yet their long-term reliability under realistic service conditions remains poorly characterized, particularly in the presence of potential reactive contaminants. In this work, we investigate the aging behavior of high-density polyethylene (HDPE), nylon-6/6 polyamide (PA), and poly(vinylidene fluoride) (PVDF) exposed to a natural gas mixture containing 0.5% oxygen as a model reactive contaminant. Using dynamic mechanical analysis (DMA), time–temperature superposition (TTS), and Fourier-transform infrared spectroscopy (FTIR), we characterize the evolution of mechanical properties, viscoelastic relaxation dynamics, and chemical structure under accelerated aging conditions with elevated temperature and pressure. While conventional mechanical properties provide ambiguous and often noisy metrics, we observe a pronounced reduction in the activation energy Ea associated with segmental relaxation across all polymers, indicating accelerated molecular dynamics. The presence of oxygen significantly enhances this effect, particularly at early aging times. We classify the aging response based on whether activation energy Ea recovers after the polymer is removed from the gas environment. For HDPE, PVDF, and PA samples aged at room temperature, the decrease in Ea recovers almost entirely once the polymers are removed from the natural gas environment, consistent with physical absorption. By contrast, PA samples aged at 90 °C exhibit only partial recovery of mechanical properties and persistent FTIR features, indicating chemical changes induced by the oxygenated environment. These results demonstrate that viscoelastic measurements can distinguish between reversible and irreversible degradation processes that may not be detected by conventional measurements.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Distinguishing Reversible Plasticization and Irreversible Degradation in Polymeric Liners — Science Skim