Rational Donor-Acceptor Design of Dye-Doped Conjugated Polymer Nanoparticles for Ratiometric Oxygen Sensing: Toward Hydrogel Platforms for Corneal Hypoxia Monitoring.
Rocío Natera Abalos, Rodrigo A Ponzio, M Emilia Zambroni, Luis E Ibarra, Sol R Martínez, Carlos A Chesta, María Lorena Gómez, Rodrigo E Palacios
Instituto de Investigaciones en Tecnologías Energéticas y Materiales Avanzados (IITEMA), Universidad Nacional de Río Cuarto (UNRC), Consejo Nacional de Investigaciones Científicas y Tecnológicas (CONICET), Río Cuarto, CórdobaX5804BYA, Argentina. · Departamento de Física, Facultad de Ciencias Exactas, Fisicoquímicas y Naturales, Universidad Nacional de Río Cuarto, Rio CuartoX5800BYA, Argentina.
Key points
From the paper's conclusion- We present a ratiometric optical oxygen sensor based on conjugated polymer nanoparticles (NP) of poly(fluorene-alt-benzothiadiazole) (F8BT) doped with platinum tetrabenzoporphyrin (BPPt).
Abstract
Corneal hypoxia, often induced by contact lens wear, is a precursor to severe ophthalmological pathologies. Early detection requires sensitive, noninvasive oxygen monitoring tools. We present a ratiometric optical oxygen sensor based on conjugated polymer nanoparticles (NP) of poly(fluorene-alt-benzothiadiazole) (F8BT) doped with platinum tetrabenzoporphyrin (BPPt). Spectral overlap between F8BT emission and BPPt absorption promotes efficient energy transfer to the porphyrin. Intersystem crossing then populates its triplet state (3BPPt*), whose phosphorescence is quenched by O2, whereas F8BT fluorescence is O2-insensitive and serves as the internal reference. The first design criterion concerns the choice of dopant: BPPt was selected because 3BPPt* lies energetically below 3F8BT* thereby limiting reverse triplet energy transfer and preserving BPPt phosphorescence. Monte Carlo simulations, constrained by two independent sets of experimental data, indicate that BPPt can deactivate the polymer by a second route that does not populate 3BPPt*. This led to a second design criterion: the doping level must be optimized for balanced dual emission, not for maximum energy transfer. The overall design yields a robust ratiometric sensor in aqueous suspension, with an estimated detection limit of 0.002 mM O2 and a reversible response over repeated O2/N2 cycling. Response times are practical (t90 < 20 s in hydrogel) and likely limited by mass transport. These sensor NP were incorporated into a poly(2-hydroxyethyl methacrylate) (pHEMA) model hydrogel relevant to contact-lens materials. The hydrogel-sensor composite retained ratiometric oxygen-sensing capability and the model matrix remained transparent and swellable; preliminary non-ocular cell assays showed no detectable acute cytotoxicity under the conditions tested. These results establish proof of concept for preserving the sensor function after immobilization in a hydrated pHEMA matrix relevant to future corneal-oxygen-sensing studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Contact lens with stretchable distributed-feedback laser for intraocular pressure monitoringarXiv · 2026
- Membrane-Anchored Phosphorescent Porphyrins as Cell-Surface Oxygen Sensors.Angewandte Chemie (International ed. in English) · 2026
- Photodynamic Antibacterial Nanofibers with Tunable Pro- and Antioxidant Activity via N,S-Doped Carbon Quantum Dots for Corneal Tissue EngineeringACS Applied Materials & Interfaces · 2025
- Nontoxic Dual-Function Probe for Ratiometric Oxygen Sensing and Cellular Imaging Based on Ir III –Eu III -Functionalized SiO₂ ParticlesACS Omega · 2026
- N, S Co‐Doped Carbon Quantum Dots‐Riboflavin Composite Photosensitizers for Enhanced Iontophoresis‐Assisted Corneal Cross‐LinkingAdvanced Science · 2026
- Coupled Molecular Crowding and Spatial Confinement Enable Reversible Sensing of Dissolved Chlorine Dioxide.ACS sensors · 2026