Key points

From the paper's conclusion
  • Beyond glucose sensing, this work establishes a general materials design strategy in which chemical functionalization transforms n-type OMIECs into conductive biointerfaces that simultaneously simplify device fabrication and provide stable bioreceptor integration for next-generation bioelectronic technologies.

Abstract

Organic mixed ionic-electronic conductors (OMIECs) have emerged as key materials for bioelectronics owing to their ability to couple ionic and electronic transport. However, their potential as multifunctional biointerfaces for biosensing remains largely untapped, particularly for n-type systems. Here, we report a hydroxy-functionalized n-doped poly(benzodifurandione) (PBFDO-OH) that unifies efficient electron transport and enzyme immobilization within a single material platform. By introducing terminal hydroxy groups into the polymer backbone, PBFDO-OH enables the direct immobilization of glucose dehydrogenase through a simple one-pot strategy, eliminating the gold substrates, self-assembled monolayers, and multistep surface activation protocols that underpin conventional biosensor fabrication. This streamlined approach yields robust biofunctional electrodes with enhanced electrochemical performance while preserving enzyme activity and long-term stability. Integrated with additively manufactured electrodes, the resulting glucose biosensor demonstrates a high sensitivity of 17.4 μA L mmol-1, a low detection limit of 3.42 μmol L-1, excellent reproducibility (RSD = 5.35%), reliable quantification in human serum (RSD < 10%), and outstanding operational stability over three weeks (RSD < 3%). Beyond glucose sensing, this work establishes a general materials design strategy in which chemical functionalization transforms n-type OMIECs into conductive biointerfaces that simultaneously simplify device fabrication and provide stable bioreceptor integration for next-generation bioelectronic technologies.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers