Remote Coacervate Robots with Visualized Bacteria Sensing and Removal in Indwelling Catheters for Infection Prevention.
Changshun Hou, Yichao Chen, Xingguang Duan
College of Medical Engineering, Beijing Institute of Technology, Zhuhai519088, P. R. China. · Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong999077, P. R. China.
Key points
From the paper's conclusion- Here we report a point-of-care sensing technique using untethered coacervate robots, which demonstrate high controllability and adaptation in confined catheters filled with viscous urine.
Abstract
Catheter-associated urinary tract infections (CAUTIs) have been a common but challenging disease due to difficulties in the accurate prescribing of antibiotics, while existing clinical diagnostic methods are deficient in their quickness, simplicity, and convenience. Here we report a point-of-care sensing technique using untethered coacervate robots, which demonstrate high controllability and adaptation in confined catheters filled with viscous urine. Under different motion modes, the controlled coacervate robots can achieve a quick, visualized, and selective fluorescence response to Gram-negative bacteria from 102 CFU/mL to 107 CFU/mL in human urine as well as remove the colonized bacteria in the inner wall of catheters within 5 min. Blind tests on clinical urine samples with various bacterial infections reveal that the coacervate robots achieve 90% sensitivity and 100% specificity in identifying Gram-negative bacteriuria. The visualized sensing technique opens up a pathway for quick onsite diagnosis, which helps prevent infections associated with urinary catheters.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Multifunctional Bacteria-Imprinted Polymer-Coated CNT Ribbons for Scalable Capture, Detection, and Elimination of Bacteria.Small (Weinheim an der Bergstrasse, Germany) · 2026
- AI-Assisted Viable Digital Array for Rapid Quantification of Bacteria in Pediatric Urinary Tract Infections.ACS sensors · 2026
- Nanoparticles in the treatment of urinary tract infections: a comprehensive review.Nanotechnology · 2026
- Cell-Surface-to-Solution Signal Transduction via a CRISPR/Cas12a-Based Dual-Target Aptamer Sensor for Detecting Urothelial Carcinoma Cells in Urine.Analytical chemistry · 2026
- Comparative analysis of biofilm detection methods and antibiotic resistance in catheter-associated uropathogens: a cross-sectional study from SyriaBMC Microbiology · 2025
- Paper-based colourimetric biosensor for simultaneous detection of UTI-associated nitrite and β-lactamase-mediated resistance using an iodometric method.Enzyme and microbial technology · 2026