Nano LettersElectrochemiluminescence

Multifunctional PTCA/GO for a Glucose-Driven Electrochemiluminescence Biosensor

Jingxian Li, Ran Zhang, Su-Ping Deng, Ningbo Zhang, Dan Yang, Abing Duan, Zhuo Chen, Hongfen Yang,

Hunan University · Ministry of Education of the People's Republic of China

Key points

From the paper's conclusion
  • Finally, a novel ECL biosensor was fabricated based on the PTCA/GO-glucose system for the ultrasensitive detection of glucose and alkaline phosphatase (ALP).

Abstract

The self-decomposition of hydrogen peroxide inevitably hinders the sensitivity and luminous efficiency of 3,4,9,10-perylene tetracarboxylic acid (PTCA) in electrochemiluminescence (ECL) systems. For the first time, as a new and advanced coreactant, glucose was efficiently activated by PTCA/graphene oxide (PTCA/GO) to generate numerous reactive oxygen species (ROS) for triggering the ECL emission of PTCA. PTCA/GO exhibits excellent glucose oxidase-like and catalase (CAT)-like activities to achieve the in situ generation and accumulation of hydroxyl radicals (·OH) and superoxide radicals (O 2 •– ). Meanwhile, the oxygen reduction reaction (ORR) of PTCA/GO follows a four-electron pathway to produce more ·OH and O 2 •– . The as-accumulated ·OH and O 2 •– subsequently react with PTCA anion radicals (PTCA •– ) to emit strong ECL signals. Finally, a novel ECL biosensor was fabricated based on the PTCA/GO-glucose system for the ultrasensitive detection of glucose and alkaline phosphatase (ALP).

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers