The Journal of Physical Chemistry COpen accessElastic recoil detection

Sensing of Hydrogen Diffusion through Protective Caps: An Ellipsometric Approach to Estimate Hydrogen Content in Pd/Hf Stacks with an Al₂ O₃ Cap

Weihua Wu, Robbert W. E. van de Kruijs, D. J. Gravesteijn, Z. Silvester Houweling, Giorgio Colombi, Alexey Y. Kovalgin

University of Twente · ASML (Netherlands)

Key points

From the paper's conclusion
  • An analytical SE model was developed for analyzing the H-content incorporated into this stack through the Al 2 O 3 capping layer, showing a decent match with that from absolute quantification by elastic recoil detection analysis.

Abstract

In this work, we develop and validate a spectroscopic ellipsometry (SE) approach to first monitor the performance of a thin-film palladium/hafnium (Pd/Hf) hydrogen detection sensor suitable for applications up to a temperature of 450 °C and second to quantify the hydrogen permeation through thin capping layers. A 2.5 nm aluminum oxide (Al 2 O 3 ) thin film is tested as a potential protective hydrogen barrier under hydrogen radical (H*) flux conditions found in extreme ultraviolet lithography scanners. To this end, the interaction between molecular and atomic hydrogen and a Pd/Hf stack was studied at temperatures from 120 to 670 °C. Optical and structural changes during hydrogen exposures were investigated using in situ SE and ex situ X-ray diffraction. The stack is confirmed to remain stable in the respective metallic phases during vacuum annealing up to 450 °C without forming any crystalline HfO 2 by reaction with trace oxidative species. Upon molecular H 2 exposure, the formation of hafnium hydride (HfH x ) can be observed for temperatures up to 350 °C, while Hf oxidation occurs at higher temperatures. Upon exposure to H*, HfH x formation is observed for temperatures up to 450 °C, again followed by oxidation at higher temperatures. Capping the stack with a 2.5 nm Al 2 O 3 layer fabricated by atomic layer deposition led to a retardation of 70 times for hydrogenation upon H* exposure at 450 °C accompanied by little oxidation. An analytical SE model was developed for analyzing the H-content incorporated into this stack through the Al 2 O 3 capping layer, showing a decent match with that from absolute quantification by elastic recoil detection analysis.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Sensing of Hydrogen Diffusion through Protective Caps: An Ellipsometric Approach to Estimate Hydrogen Content in Pd/Hf Stacks with an Al₂ O₃ Cap — Science Skim