Redox-Dependent 1H and 19F Relaxation of a Fluorinated Mn–Diimidazolyl Porphyrin Complex
Daniela S. S. Teixeira, Tomás M. Domingues, Zoltán Garda, Hervé Meudal, Fédérico Perche, Frédéric Szeremeta, Mariette M. Pereira, Carlos F. G. C. Geraldes,
Key points
From the paper's conclusion- To improve hydrosolubility, we have introduced two quaternized methylimidazole functions on the porphyrin complex Mn(III)-6 bearing two CF3 groups.
Abstract
Complexes of redox active, paramagnetic transition metal ions, such as manganese, are under scrutiny as potential magnetic resonance imaging (MRI) probes for the assessment of the tissue redox state, and the use of fluorinated ligands can afford dual 1H and 19F MRI detection. While porphyrins are excellent chelators for both oxidized Mn(III) and reduced Mn(II) states, the low aqueous solubility of the complexes often limits application, especially for fluorinated derivatives. To improve hydrosolubility, we have introduced two quaternized methylimidazole functions on the porphyrin complex Mn(III)-6 bearing two CF3 groups. Mn(III)-6 can be reduced by ascorbic acid (AA) or carboxylate-protected cysteine, and Mn(II)-6 is reoxidized by air oxygen. In DMSO/H2O mixtures, both reduction and oxidation reactions are strongly affected by the solvent composition, likely related to the different reducing power of ascorbate and to different Mn-porphyrin aggregation states. The reduction from Mn(III)-6 to Mn(II)-6 is accompanied by important variation in the proton relaxivities with the exception of 30 and 400 MHz, where the nuclear magnetic relaxation dispersion (NMRD) curves of the complexes intersect. The 19F relaxation times become shorter upon reduction (∼ 30% decrease for T1 and 70% for T2; 9.4 T, 25 °C). The 19F MRI signal recorded by a FLASH sequence can be detected for the Mn(III)-6 form with a good signal-to-noise ratio, which is proportional to the Mn(III)-6 concentration. Upon reduction with ascorbic acid, the progressive decrease of the 19F MRI signal is directly reporting on the reaction progress.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Trans-1,2-Diphenyl-Substituted EDTA Platform for High-Relaxivity Mn(II) MRI Probes.Chemistry (Weinheim an der Bergstrasse, Germany) · 2026
- SingleMolecule Eu2+/3+ Complex Platformfor Optical and Magnetic Resonance Imaging In VivoJournal of the American Chemical Society · 2026
- A Rigid, Mono(Aquated) Mn(II)-Based Complex as MRI Contrast Agent for the Liver and Brain Vasculature Imaging.Journal of medicinal chemistry · 2026
- Histamine-poly(maleic anhydride) conjugate improves selective cellular uptake of Fe3O4 magnetic nanoparticles for dual-modal MRI/SPECT cancer imaging.RSC advances · 2026
- Multifunctional Melanin Nanoparticles: Synthesis, Characterization, and Magnetic Resonance Imaging-Guided Biomedical Applications.Materials (Basel, Switzerland) · 2026
- Manganese-Enhanced Magnetic Resonance Imaging: From Translational Research to First-in-Human Trials in Oncology.Molecular diagnosis & therapy · 2026