Journal of the American Chemical SocietyOpen accessChemistry

SingleMolecule Eu2+/3+ Complex Platformfor Optical and Magnetic Resonance Imaging In Vivo

Carter B. Rodgers, Morgan P. Deal, Leah C. Garman, Ilia A. Guzei, Matthew J. Allen, Eszter Boros

University of Wisconsin System · Wayne State College

Preclinical

Key points

From the paper's conclusion
  • The complex that provided the greatest signal-to-noise ratio in magnetic resonance in vitro imaging studies, and when oxidized, produced a detectable, optical imaging signal with as little as 5 nmol of complex.

Abstract

Abstract Lanthanide coordination complexes are harnessed for biological imaging due to their oxidative stability in aqueous media, favorable relaxometric behavior, and accessible luminescence emissions within biomedically relevant, optical-imaging wavelength ranges. In contrast with multimodal imaging strategies that rely on exchanging lanthanide ions to access distinct modalities, we exploit the unique redox chemistry of the Eu2+/3+ pair to demonstrate the feasibility of multimodal imaging within a single chelate scaffold. We constructed a series of polypyridine-containing macrocyclic ligands that readily coordinate both Eu2+ and Eu3+ ions. Characterization of the corresponding chelates by X-ray crystallography, cyclic voltammetry, electron paramagnetic resonance spectroscopy, and photophysical measurements were conducted. The Eu2+-containing complexes of acetamide-functionalized, polypyridine-containing 18-membered macrocycles exhibit relaxometric properties comparable to clinical Gd3+ contrast agents for magnetic resonance imaging. Upon oxidation to Eu3+, the complexes display characteristic luminescence with quantum yields ranging from 1.3 to 13.9%. In situ sensitization with a Cherenkov-emitting radionuclide efficiently produces Eu3+ emission at concentrations comparable to those employed for Eu2+-enhanced magnetic resonance imaging. The complex that provided the greatest signal-to-noise ratio in magnetic resonance in vitro imaging studies, and when oxidized, produced a detectable, optical imaging signal with as little as 5 nmol of complex. A subsequent study in a murine xenograft tumor model demonstrated the feasibility of conducting sequential magnetic resonance and optical imaging experiments following single dose administration of the redox–switchable complex.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers