Multiplex Isotope Tagging-Electromembrane Extraction of Metabolites with Diverse Polarities.
Yangyang Liu, Li Chen, Shengtao Ma, Stig Pedersen-Bjergaard, Chuixiu Huang, Xiantao Shen
Key Laboratory of Health Effects of Environmental Pollution, Ministry of Ecology and Environment, State Key Laboratory of Environmental Health (Incubation), School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, Wuhan430030, China. · School of Public Health, Guangzhou Medical University, Guangzhou511436, P. R. China.
Key points
From the paper's conclusion- The labeling increased the lipophilicity of the carnitines (0.9 ≤ log P ≤ 4.6), thereby increasing the partition coefficient by more than two orders of magnitude and the transmembrane flux by up to 43.9-fold, ultimately enabling efficient simultaneous extraction of polar and non-polar carnitines with recoveries of 62−95%.
Abstract
In this work, a multiplex isotope tagging-electromembrane extraction (MIT-EME) strategy was proposed to address two critical drawbacks of conventional EME in metabolite analysis: failure to simultaneously extract polar and non-polar metabolites, and limited analytical throughput. Specifically, seven carnitines covering the hydrophobicity (log P) range of -0.5 to 3.2 were selected as model analytes, and were studied in human serum samples. The carnitines were labeled with p-dimethylaminophenacyl (DmPA) bromide and its two isotopic analogues for sample encoding. Labeled samples were then pooled and subjected to EME and liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis. The labeling increased the lipophilicity of the carnitines (0.9 ≤ log P ≤ 4.6), thereby increasing the partition coefficient by more than two orders of magnitude and the transmembrane flux by up to 43.9-fold, ultimately enabling efficient simultaneous extraction of polar and non-polar carnitines with recoveries of 62-95%. The MIT-EME-LC-MS/MS method provided satisfactory limits of detection (0.02-0.09 ng mL-1), accuracy (90-113%), precision (≤14%), and matrix effects (90-107%). Benefiting from isotopic multiplexing, samples were pooled and analyzed in a single LC-MS/MS run, and achieved the synchronous analysis of three serum samples. The method was applied to serum samples from 100 hyperuricemia patients and 200 healthy individuals, and obvious intergroup differences of serum carnitines were observed. The strategy developed in this study provides a powerful approach for large-scale metabolomics analysis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Systematic evaluation of SPE cartridges in a 12-second SPE-IM-MS workflow for untargeted intracellular metabolomicsScientific Reports · 2026
- Integrated Fe(III)-driven liquid-phase microextraction-spectrophotometry for selective and high-throughput detection of ethyl maltol in complex food samples.Analytical and bioanalytical chemistry · 2026
- Development and systematic evaluation of an untargeted HILIC‑HRMS metabolomics workflow for multi-matrix human samples analyses.Metabolomics : Official journal of the Metabolomic Society · 2026
- Single‐Injection Multi‐Omics Analysis by Direct Infusion Mass SpectrometryAngewandte Chemie International Edition · 2026
- B-367 Evaluation of a Weak Cation Exchange-based Magnetic Bead Extraction Method for Plasma Metanephrines Using LC–MS/MSClinical Chemistry · 2026
- B-337 A Rapid and Selective LC-MS/MS Workflow for Methylmalonic Acid Using Strata™ SE SLEClinical Chemistry · 2026