Overcoming Ru-99 Isobaric Overlap via C2H4 as a Reaction Gas for Tc-99 Accurate Measurement in Large-Volume Seawater Samples by Triple Quadrupole ICP−MS with Mass-Shift Mode
Yiman Lu, Jie Chen, Shan Xing, Man Wang, Hao Wang, Feng Zhang, Xinyu Du, Chenyang Peng,
Key points
From the paper's conclusion- This method is expected to directly and accurately measure ultra-trace level 99Tc in large-volume seawater samples without any mathematical correction of 99Ru.
Abstract
Accurate determination of ultra-trace level 99Tc in environmental samples is primarily hindered by the interferences of 98Mo and 99Ru. For the “elimination” of the 99Ru isobaric overlap during the mass spectrometry measurement, the commonly-used method of mathematical correction based on a known isotopic ratio of Ru (e.g., 99Ru/102Ru) could lead to a high measurement uncertainty of 99Tc. In this work, a direct and accurate analytical method of 99Tc in large-volume seawater samples (>20 L) was developed using two TEVA resin columns in combination with ICP−MS/MS in He−C2H4 mode. Both Fe(OH)2 and Ti(OH)3 were used as co-precipitants for the pre-concentration of 99Tc in large-volume seawater samples, and then, 99Tc was purified by two serial TEVA resin columns with the high decontamination factors of Mo (5×105) and Ru (1×105). Based on the high reactivity of C2H4, the residual interferences of 98Mo and 99Ru were completely removed in the mass-shift mode for the first time. Excellent decontamination factors of 98Mo (1×1012) and 99Ru (1.6×109) were achieved in the whole procedure, which was 3−4 orders of magnitude higher than these of traditional methods. The detection limit of 0.015 pg/L for 99Tc was obtained, and the whole analysis time was less than 20 h per sample. This method is expected to directly and accurately measure ultra-trace level 99Tc in large-volume seawater samples without any mathematical correction of 99Ru.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Quantitative Pertechnetate Capture by a Bambusuril-based Material: From Seawater Decontamination to Radiopharmaceutical Solutions.Angewandte Chemie (International ed. in English) · 2026
- Application of solid phase extractants TEVA and TK200 for the separation of medically relevant 199Au from thermal neutron irradiated Pt target.Journal of chromatography. A · 2026
- New hydrophilic triple-charged cationic receptors for binding pertechnetate and perrenate anions in acidic aqueous solutions.Dalton transactions (Cambridge, England : 2003) · 2026
- Selective Capture of 99TcO4-/ReO4- Using a Novel Functionalized Cationic Organic Polymer via Synergistic Electrostatic-Chelation Interactions.Langmuir : the ACS journal of surfaces and colloids · 2026
- High-resolution neodymium isolation from adjacent lanthanides by synergistic extraction chromatography for nuclear fuel burnup analysis.Journal of chromatography. A · 2026
- Determination of rhenium in sea and fresh water samples by coupling cadmium and iron ion-assisted photochemical vapor generation to inductively coupled plasma mass spectrometrySpectrochimica Acta Part B Atomic Spectroscopy · 2026