Journal of chromatography. A

Application of solid phase extractants TEVA and TK200 for the separation of medically relevant 199Au from thermal neutron irradiated Pt target.

A N Veleshko, D A Uchkina, E B Furkina, T M Fazliev, V N Kochkin, A A Reshetnikov, E N Poznyrev, I A Soglasov,

NBIC Department, National Research Centre "Kurchtov institute", Kurchatov sq.1, Moscow, 123182, Russian Federation. Electronic address: Veleshko_AN@nrcki.ru. · NBIC Department, National Research Centre "Kurchtov institute", Kurchatov sq.1, Moscow, 123182, Russian Federation.

Key points

From the paper's conclusion
  • This study describes the separation of no-carrier-added (n.c.a.) 199Au from thermal neutron irradiated natural platinum targets using two extraction chromatographic resins: TEVA containing a quaternary amine (Aliquat 336) and TK200 impregnated with trioctylphosphine oxide (TOPO, Cyanex 921).

Abstract

This study describes the separation of no-carrier-added (n.c.a.) 199Au from thermal neutron irradiated natural platinum targets using two extraction chromatographic resins: TEVA containing a quaternary amine (Aliquat 336) and TK200 impregnated with trioctylphosphine oxide (TOPO, Cyanex 921). The behavior of Au, Pt, and Ir in HCl media (0.1-10 mol·L-1 HCl) is examined through batch distribution coefficient (Kd) measurements and dynamic column experiments. For TEVA, the Kd of Au remains high across the entire HCl range (2-3·104 mL·g-1), whereas Pt shows a maximum Kd of 3.3·104 mL·g-1 at 1 mol·L-1 HCl, decreasing at higher HCl concentration. Iridium exhibits low Kd values ((10-4.6·102 mL·g-1), consistent with its presence as trivalent species forming weaker complexes with quaternary amines. For TK200, Au Kd ranges from 2·105 to 5·105 mL·g-1, with a slight decrease at high acidity. Pt(IV) reaches a maximum Kd of 2.2·104 mL·g-1 at 1 mol·L-1 HCl. A notable increase in Ir Kd is observed below 1 mol·L-1 HCl, attributed to hydrolysis of iridium chloro complexes. Based on these distribution data, column separation is achieved in acidic media using 1 g of chromatographic resins. Gold is eluted using dilute HCl with thiourea. The separation factors (SFPt/Au) are 1.6·104 for TEVA and 5.9·104 for TK200, while the Pt decontamination factors are 158 and 650, respectively, with overall 199Au yields of 97.6% and 94.1%. The dynamic Pt capacities at 1 mol·L-1 HCl are 0.13 mmol·g-1 for TEVA and 0.22 mmol·g-1 for TK200. The developed separation schemes provide efficient methods for producing medically relevant n.c.a. 199Au from irradiated platinum targets.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers