Aptamer-Based Fluorescent Assays for Detection of the Host-Response Viral Biomarker 3'-Deoxy-3',4'-Didehydro-Cytidine.
Ravi Mehta, Sondes Ben-Aissa, Kyungae Yang, Elena Chekmeneva, Maria Valdivia-Garcia, Lynn Maslen, Trevor Ferris, Kamil Skirlo,
Department of Infectious Disease, Imperial College London, LondonW12 0NN, U.K. · Department of Chemistry, Imperial College London, LondonW12 0BZ, U.K.
Key points
From the paper's conclusion- Together, these results establish aptamer-based sensing approaches for ddhC and demonstrate their feasibility in clinical urine samples, providing a foundation for further optimisation toward accessible, non-invasive, and rapid detection of acute viral infection.
Abstract
Improved viral diagnostics are urgently needed to strengthen pandemic preparedness and combat antimicrobial resistance, highlighting the importance of 3'-deoxy-3',4'-didehydro-cytidine (ddhC), a host-derived, pan-viral biomarker that addresses key limitations of PCR-based diagnostics. Current methods for ddhC measurement rely on liquid chromatography-mass spectrometry (LC-MS) or nuclear magnetic resonance spectroscopy, which are accurate but costly and impractical for rapid or point-of-care testing. Here, we report the development of aptamer-based fluorescent assays for selective ddhC detection. Low-micromolar-affinity DNA aptamers were isolated using capture-systematic evolution of ligands by exponential enrichment (SELEX) and characterised by isothermal titration calorimetry. Using a common core aptamer sequence, three fluorescence assay formats-strand displacement, molecular beacon, and dye displacement-were developed and evaluated. Independent LC-MS analysis demonstrated a strong correlation between creatinine-normalised urinary and serum ddhC concentrations in inpatient samples (R = 0.98, p <0.0001), supporting urine as a non-invasive matrix for ddhC detection. Among the three aptamer-based formats tested, the dye displacement assay exhibited the lowest functional Kd but was limited in urine by inner filter effects, whereas a Cy5-labelled strand displacement assay overcame this limitation and detected ddhC in patient urine with moderate correlation to LC-MS (R = 0.76, p = 0.001). Together, these results establish aptamer-based sensing approaches for ddhC and demonstrate their feasibility in clinical urine samples, providing a foundation for further optimisation toward accessible, non-invasive, and rapid detection of acute viral infection.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Dual-aptamer magnetic capture and electrochemical detection of influenza B and respiratory syncytial viruses in artificial saliva.The Analyst · 2026
- Microbead-Based Heterodimer Assay for Amplification-Free Detection of Single-Stranded DNAbioRxiv · 2026
- Integrated recombinase-aided amplification–invader system: a closed-tube visual platform for hepatitis B virus detectionFrontiers in Cellular and Infection Microbiology · 2026
- Chimeric ascorbic acid phosphate-releasing nucleotide probes for isothermal signal-amplified protein detection.Talanta · 2026
- A Dual-Amplification DNA Fluorescence Biosensor Based on Strand Displacement.IEEE transactions on nanobioscience · 2026
- Field-Deployable Nucleic Acid Testing via Functional Double-Strand to Single-Strand Conversion.Analytical chemistry · 2026