Dual-Wavelength OA-ICOS for Sensitive and Wide-Range In Situ Measurement of Dissolved Methane in Deep-Sea Cold Seeps.
Mingsi Gu, Jingru Chen, Jiajin Chen, Jiaoxu Mei, Guishi Wang, Tu Tan, Kun Liu, Xiaoming Gao
Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei230031, China.
Key points
From the paper's conclusion- These results show that the dual-wavelength OA-ICOS strategy can support continuous, quantitative methane measurements across strongly heterogeneous deep-sea seepage environments.
Abstract
Dissolved methane in deep-sea cold seeps can vary from background levels to highly enriched seep water over short spatial scales, which requires in situ measurements with both high sensitivity and a wide dynamic range. Single-transition laser absorption measurements often face a trade-off: strong absorption lines improve low-concentration detection but can saturate at high methane concentrations, whereas weak lines extend the measurable range but reduce the sensitivity. We developed a dual-wavelength off-axis integrated cavity output spectroscopy analyzer for the continuous in situ measurement of dissolved methane in deep-sea environments. The system uses methane transitions near 1651 and 1658 nm to combine trace-level detection with high-concentration quantification. Gas-phase calibration showed excellent linearity for both channels (R2 > 0.999), with the 1651 nm channel calibrated over 2-20 ppm and the 1658 nm channel calibrated over 10-2000 ppm. During continuous measurement of a 10.06 ppm of CH4 standard gas, the concentration precision improved from 0.016 ppm at 20 s to 1.95 ppb at 400 s for the 1651 nm channel and from 0.69 ppm to 52 ppb for the 1658 nm channel. A membrane-based gas extraction module was then calibrated to convert optical measurements to dissolved methane concentrations. Field deployment on a manned submersible in the northern South China Sea resolved near-bottom methane enrichment, rapid vertical attenuation, and localized hotspots exceeding 250 ppm. These results show that the dual-wavelength OA-ICOS strategy can support continuous, quantitative methane measurements across strongly heterogeneous deep-sea seepage environments.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Rapid real-time monitoring of dissolved gases in seawater by cavity-enhanced Raman spectroscopy system with sub-ppm sensitivity.Talanta · 2026
- Baseline-Free Wide-Range Methane Concentration Measurement Based on Logarithmic Second Derivative Spectroscopy.Analytical chemistry · 2026
- Assessing the Detection of Methane Plumes in Offshore Areas Using High-Resolution Imaging SpectrometersAtmospheric measurement techniques · 2025
- A reconfigurable and compact circular multi-pass sensor for ultra-sensitive methane detectionJournal of Instrumentation · 2026
- Design and Performance Validation of a Low-Loss Optical System with Light Source Fluctuation Compensation for In Situ Deep-Sea Nitrate Sensing.Sensors (Basel, Switzerland) · 2026
- Microliter-scale seawater DIC measurement method using acidification-purge extraction coupled with hollow-core-waveguide-based TDLAS.Talanta · 2026